CLI Guide

SataPortH / sata7
Table 170. SataPortH / sata7
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: auto, o
On Dell’s 12th generation PowerEdge and later systems: O, Auto
Description
Turns the SATA port 7 to auto or o. This option can be replicated.
Example:
A:>syscfg --sata7=auto
sata7=auto
Applicable Systems All PowerEdge systems.
SataPortHCapacity*
Table 171. SataPortHCapacity
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: read-only
Description
Displays the total capacity of a hard-disk drive. This option is undened for removable-
media devices such as optical drives.
Example:
A:>syscfg --SataPortHCapacity
Applicable Systems PowerEdge 12G and later systems.
SataPortHDriveType*
Table 172. SataPortHDriveType
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Read-only
Description
This option indicates type of device attached to this SATA port.
Example:
A:>syscfg --SataPortHDriveType
Applicable Systems Dell’s 12th generation PowerEdge and later systems
SataPortHModel*
Table 173. SataPortHModel
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Read-only
Description
Displays the drive model of the selected device.
Example:
A:>syscfg --SataPortHModel
Applicable Systems Dell’s 12th generation PowerEdge and later systems
SataPortI / sata7
Table 174. SataPortI / sata7
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: auto, o
82