CLI Guide

Example:
A:>syscfg --SataPortBDriveType
Applicable Systems Dell’s 12th generation PowerEdge and later systems
SataPortBModel*
Table 149. SataPortBModel
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Read-only
Description
Displays the drive model of the selected device.
Example:
A:>syscfg --SataPortBModel
Applicable Systems Dell’s 12th generation PowerEdge and later systems
SataPortC / Sata2
Table 150. SataPortC / Sata2
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: auto, o
On Dell’s 12th generation PowerEdge and later systems: O, Auto
Description
Turns the SATA port 2 to auto or o. This option can be replicated.
Example:
A:>syscfg --sata2=auto
sata2=auto
Applicable Systems All PowerEdge systems
SataPortCCapacity*
Table 151. SataPortCCapacity
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Read-only
Description
Displays the total capacity of a hard disk drive. This option is undened for removable-
media devices such as optical drives.
Example:
A:>syscfg --SataPortCCapacity
Applicable Systems Dell’s 12th generation PowerEdge and later systems
SataPortCDriveType*
Table 152. SataPortCDriveType
Valid Arguments
On systems prior to Dell’s 12th generation PowerEdge systems: NA
On Dell’s 12th generation PowerEdge and later systems: Read-only
Description
Indicates the type of device attached to the SATA port.
Example:
A:>syscfg --SataPortCDriveType
Applicable Systems Dell’s 12th generation PowerEdge and later systems
77