CLI Guide

Table 314. pefcgparams
Option Sub-option Valid Arguments Description Applicable Systems
pefcfgparams
or pcp
Congures and displays PEF
conguration parameters. This option
can be replicated.
All PowerEdge systems
--filter fanfail,
voltfail,
discretevolt
fail,
tempwarn,
tempfail,
intrusion,
redundegrade
d,redunlost,
procwarn,
procfail,
powerwarn,
powerfail,
hardwarelogf
ail,
autorecovery
,
batterywarn,
batteryfail,
powerabsent,
procabsent,
systempowerw
arn,
systempowerf
ail
Species
a PEF value. This sub-option
can be replicated.
For a complete list of all possible PEF
messages along a description of each
event, see BMC Platform Events Filter
Alert Messages
NOTE: The fanfail option is
not supported on PowerEdge
10G systems.
--filteraction
powercycle,
reset,
powerdown,
power
reduction,
none
Sets the event lter action for the
lter specied using the filter sub-
option. This sub-option depends on
the filter sub-option. This sub-
option can be replicated.
--hostname <string>
Sets the host name (maximum of 62
printable ASCII characters) for the
BMC. This sub-option can be
replicated.
The hostname string must comprise
only the followig characters: hyphen
(-) , underscore (_) , and period (.) .
The length of the hostname string
must be 62 characters or less for
PowerEdge 9G systems and later.
--filteralert
enable,
disable
Enables or disables alerts for the lter
specied using the lter sub-option.
This sub-option is dependent on the
lter sub-option. This sub-option can
be replicated.
--alertpolnum 1, 2, 3, 4
Species the alert policy entry number.
This sub-option can be replicated.
--
alertpolstatus
enable,
disable
Enables or disables the alert policy
specied using the alertpolnum
sub-option. This sub-option can be
133