CLI Guide

Option Sub-option Valid Arguments Description
powerfail,
hardwarelogfail,
autorecovery,
batterywarn,
batteryfail,
powerabsent,
procabsent,
systempowerwarn,
systempowerfail
--filteraction
powercycle,
reset,
powerdown, power
reduction, none
Sets the event lter action for the lter specied
using the filter sub-option. This sub-option
depends on the filter sub-option. This sub-
option can be replicated.
--hostname <string>
Sets the host name (maximum of 62 printable
ASCII characters) for the BMC. This sub-option
can be replicated.
The hostname string must comprise only the
followig characters: hyphen (-) , underscore (_) ,
and period (.) .
--filteralert enable, disable
Enables or disables alerts for the lter specied
using the lter sub-option. This sub-option is
dependent on the lter sub-option. This sub-
option can be replicated.
--alertpolnum 1, 2, 3, 4
Species the alert policy entry number. This
sub-option can be replicated.
--alertpolstatus enable, disable
Enables or disables the alert policy specied
using the alertpolnum sub-option. This sub-
option can be replicated. This sub-option is
dependent on the alertpolnum sub-option.
Example: (to set the PEF conguration
parameters):
Example 1 (To congure the PEF so that the
system is powered down in response to a fan
failure event):
A:>syscfg pefcfgparams --filter=
fanfail--filteraction=powerdown
pefcfgparams filter=fanfail
filteraction=powerdown
Example 2 (To congure the PEF so that a PEF
alert is not sent to the destination IP address in
response to a chassis intrusion event):
A:>syscfg pefcfgparams --filter=
intrusion--filteralert=disable
pefcfgparams filter= intrusion
filteralert=disable
132