CLI Guide
loaddefaults*
Table 309. loaddefaults*
Option Sub-option Valid Arguments Description
--loaddefaults*
NA NA
Restores the BMC to the defaults originally loaded
on the controller. This option is used to return the
BMC to a known-good state. This option cannot be
replicated.
NOTE: The NMI, power button, and SOL
defaults are not reset by using this option.
Example:
A:>syscfg --loaddefaults
Loading defaults...
nextboot
Table 310. nextboot
Option Sub-option Valid Arguments Description
--nextboot or --
OneTimeBootSeqDev
NA valid device name
(from the bootseq
option device list)
Sets the specied device as the rst device in
the boot order for the next boot cycle only. The
device must be a device from the bootseq
option device list. Run the bootseq option to
see a list of available device names. For more
information, see
--bootseq. This option is not
replicated.
Example 1:
A:>syscfg --bootseq
Device 1: floppy.emb.0 -
Diskette Drive A:
Device 2: cdrom.emb.0 - CD-ROM
device
Device 3: hdd.emb.0 - Hard Drive
C:
Device 4: nic.emb.1 - Intel Boot
Agent Version 4.0.17
Device 5: nic.emb.2 - Intel Boot
Agent Version 4.0.17
Example 2:
A:>syscfg --nextboot=nic.emb.1
nextboot=nic.emb.1
nmibutton
Table 311. nmibutton
Option Sub-option Valid Arguments Description
--nmibutton
NA
enable, disable
Enables or disables the NMI button. This option
can be replicated.
130