CLI Guide

Example:
A:>syscfg --memintleave=enable
memintleave=enable
NOTE: The memintleave option is same as Nodeinterleave option. For more
information, see Memory Settings group.
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
memremap
Table 285. memremap
Valid Arguments o, auto
Description
Sets the memory remapping to o or auto.
Example:
A:>syscfg --memremap=off
memremap=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
mouse
Table 286. mouse
Valid Arguments on, o
Description
Turns the mouse controller on or o.
This option can be replicated.
Example:
A:>syscfg --mouse=off
mouse=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
noraidprompt*
Table 287. noraidprompt*
Valid Arguments NA
Description
Species that the BIOS must not prompt for conrmation when changing the mode of
a RAID controller. This option can only be used with the --embscsiraid or --
embscsiraidchb options.
Without this option, the user is prompted during POST to conrm the change of a RAID
controller from RAID (SCSI) to SCSI (RAID). This option is not replicated.
CAUTION: When changing a RAID controller from SCSI to RAID or from RAID
to SCSI, data is lost on the aected hard drives. The warning message for this
data is not displayed if you use the
--noraidprompt option. To avoid data loss,
back up any information on the hard drives before changing the type of
controller used with the drives
Example:
A:>syscfg --embscsiraid=raid --noraidprompt
embscsiraid=raid
120