CLI Guide
chassistype*
Table 269. chassistype*
Option Sub-option Valid Arguments Description
--chassistype*
NA NA
Identies the Chassis Management Controller
(CMC). The possible values are 9 (M1000e), 10
(VRTX), and 0 (others).
Example:
A:>syscfg -- chassistype
chassistype=10 (VRTX)
clearsel*
Table 270. clearsel*
Option Sub-option Valid Arguments Description
--clearsel*
NA NA
Clears the System Event Log (SEL). This option
cannot be replicated.
Example:
A:>syscfg -- clearsel
Clearing SEL...
controlpanelaccess
Table 271. controlpanelaccess
Option Sub-option Valid Arguments Description
--controlpanelaccess
NA
viewandmodify,
viewonly,
disabled
Sets or gets the access level for the Liquid
Crystal Display (LCD).
Example:
A:>syscfg -- controlpanelaccess=
viewandmodify
controlpanelaccess= viewandmodify
deviceguid*
Table 272. deviceguid*
Option Sub-option Valid Arguments Description
--deviceguid*
NA NA
Displays the GUID for the BMC. This option cannot
be replicated.
Example:
A:>syscfg--deviceguid
deviceguid=XXXXXXXXXX
encryptkey
Table 273. encryptkey
Option Sub-option Valid Arguments Description
--encryptkey
NA <hexadecimal number>
Encrypts the IPMI sessions.
116