CLI Guide
Example:
A:>syscfg --embscsi2=on
embscsi2=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsiraid
Table 257. embscsiraid
Valid Arguments
raid, off, scsi
Description
Sets the specied value for the SCSI RAID controller. This option is only valid for
supported systems that have SCSI ROMB. Some systems do not support the scsi
argument. This option can be replicated.
CAUTION: If you change the controller from SCSI to RAID mode, data loss
may occur. Backup any data you must save before changing modes.
Example:
A:>syscfg --embscsiraid=raid
embscsiraid=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsiraidchb
Table 258. embscsiraidchb
Valid Arguments raid, scsi
Description
Sets the second channel on an embedded RAID controller to SCSI or RAID. This option
is only valid for systems that support RAID/RAID and RAID/SCSI settings for channels
A and B. This option can be replicated.
Example:
A:>syscfg --embscsiraidchb=raid
embscsiraidchb=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsiraidchb
Table 259. embscsiraidchb
Valid Arguments raid, scsi
Description
Sets the second channel on an embedded RAID controller to SCSI or RAID. This option
is only valid for systems that support RAID/RAID and RAID/SCSI settings for channels
A and B. This option can be replicated.
Example:
A:>syscfg --embscsiraidchb=raid
embscsiraidchb=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embsdcardredundancy
Table 260. embsdcardredundancy
Valid Arguments mirrormode, disable
Description
Sets the redundancy to mirrormode or disabled.
110