CLI Guide

Table Of Contents
Table 74. MemTest/memtest (continued)
Example:
A:>syscfg --MemTest=Enabled
MemTest=Enabled
Applicable Systems All PowerEdge systems
NodeInterleave/nodeinterleave
Table 75. NodeInterleave/nodeinterleave
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables node interleaving, if the system is configured with matching memory. If
set to disable (default), the system supports Non-Uniform Memory (NUMA)
architecture memory configurations. This field is active only if the memory
configuration can support node interleaving.
NOTE: The nodeinterleave option is same as memintleave option. For
more information, see memintleave.
Example:
A:>syscfg --nodeinterleave=enable
nodeinterleave=enable
Applicable Systems All PowerEdge systems.
redmem
Table 76. redmem
Valid Arguments off, spare, mirror, DDDC
Description
Allows selection of the required redundant memory mode, or disables redundant
memory. This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
Applicable Systems PowerEdge systems with Intel Xeon 7500 series processor
SerialDbgOut
Table 77. SerialDbgOut
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: Enabled, Disabled
Description
Enables or disables the RC/MRC Serial debug output.
62 SYSCFG