CLI Guide
Table Of Contents
- Dell EMC OpenManage Deployment Toolkit Version 6.0.1 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1/embnic1
- EmbNic1Nic2/embnic1nic2
- EmbNic2/embnic2
- EmbNic3/embnic3
- EmbNic3Nic4/embnic3nic4
- EmbNic4/embnic4
- EmbVideo/embvideoctrl
- IoatEngine/ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid/integratedraid
- IntegratedSas/integratedsas
- InternalSdCard/embsdcard
- InternalSdCardRedundancy/embsdcardredundancy
- InternalUsb/internalusb
- InternalUsb1/internalusbport1
- InternalUsb2/internalusbport2
- OsWatchdogTimer/oswatchdogtimer
- SriovGlobalEnable/sriov
- UsbPorts/usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- IscsiDev1Con
ChapType - IscsiDev1Con
DhcpEnDis - IscsiDev1ConnEnDis
- IscsiDev1ConnInterface
- IscsiDev1ConnProtocol
- IscsiDev1ConnTimeout
- IscsiDev1ConnVlanEnDis
- IscsiDev1ConnVlanId
- IscsiDev1ConnAuth
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse/datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher/dcustreamerprefetcher
- LogicalProc/logicproc
- Proc1Brand*
- Proc1Id*
- Proc1L2Cache*
- Proc1L3Cache*
- Proc1NumCores*
- Proc2Brand*
- Proc2Id*
- Proc2L2Cache*
- Proc2L3Cache*
- Proc2NumCores*
- Proc3Brand*
- Proc3Id*
- Proc3L2Cache*
- Proc3L3Cache*
- Proc3NumCores*
- Proc4Brand*
- Proc4Id*
- Proc4L2Cache*
- Proc4L3Cache
- Proc4NumCores*
- Proc64bit*
- ProcAdjCacheLine/adjcacheprefetch
- ProcBusSpeed*
- ProcCores/cpucore
- ProcCoreSpeed*
- ProcExecuteDisable/cpuxdsupport
- ProcHwPrefetcher/hwprefetcher
- ProcVirtualization / virtualization
- QpiBandwidthPriority / qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata / embsataraid
- eSataPort1
- eSataPort1Capacity*
- eSataPort1DriveType*
- eSataPort1Model*
- SataPortA / sata0
- SataPortACapacity*
- SataPortADriveType*
- SataPortAModel*
- SataPortB / sata1
- SataPortBCapacity*
- SataPortBDriveType*
- SataPortBModel*
- SataPortC / Sata2
- SataPortCCapacity*
- SataPortCDriveType*
- SataPortCModel*
- SataPortD / sata3
- SataPortDCapacity*
- SataPortDDriveType*
- SataPortDModel*
- SataPortE / sata4
- SataPortECapacity*
- SataPortEDriveType*
- SataPortEModel*
- SataPortF / sata5
- SataPortFCapacity*
- SataPortFDriveType*
- SataPortFModel*
- SataPortG / sata6
- SataPortGCapacity*
- SataPortGDriveType*
- SataPortGModel*
- SataPortH / sata7
- SataPortHCapacity*
- SataPortHDriveType*
- SataPortHModel*
- SataPortI / sata7
- SataPortICapacity*
- SataPortIDriveType*
- SataPortIModel*
- SataPortJ / sata7
- SataPortJCapacity*
- SataPortJDriveType*
- SataPortJModel*
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- System Security
- AcPwrRcvry / acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt/inteltxt
- NmiButton/nmibutton
- PasswordStatus/pwdlock
- PwrButton/powerbutton
- SetupPassword/setuppwd*
- SysPassword/syspwd*
- SystemCpldVersion*
- TcmActivation/tcmactivation
- TcmClear/tcmclear
- TcmSecurity/tcmsecurity
- TpmActivation/tpmactivation
- TpmClear/tpmclear
- TpmSecurity/tpmsecurity
- TpmStatus
- TpmInfo*
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- SecureBootMode
- TpmPpiBypassClear
- TpmPpiBypassProvision
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype*
- clearsel*
- controlpanelaccess
- deviceguid*
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt*
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev*
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults*
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset*
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version*
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
BootSeq/bootseq
Table 20. SYSCFG Options Supported — BootSeq/bootseq
Valid Arguments
● On systems prior to 12G: numerical list separated by commas or list of device
names separated by commas
● On 12G and later systems: list of device names separated by commas
Description
Enables, disables, and orders the devices in a boot order list. Only the devices
present on the system are listed in the boot sequence.
NOTE: Only the devices listed in the bootseq are enabled.
Without an argument, this option prints the boot order list. The argument must
be formatted as a comma-separated numerical list with no spaces. The list must
be within the bounds of the current boot list, that is, the low and high numbers
must match, and the same number of entries must be supplied. Systems that use a
numerical list for boot order cannot be replicated.
Some systems also allow the boot order to be expressed as a list of device names.
Device names are formatted as a name.location.instance string, where name is the
name of the device, location is either slot or embedded (emb), and instance is
the numerical position of the device. Some device name examples are shown below.
Systems that support a list of device names for boot order can be replicated.
Numerical Lists Examples:
A:>syscfg --bootseq= 2,3,4,5,1,6
The following devices are set in the boot sequence:
Device 2:* usbcdrom.slot.1- USB CD-ROM device
Device 3:* virtualcd.slot.1 – VIRTUAL CDROM
Device 4:* hdd.emb.0 -Hard drive C:
Device 5:* nic.emb.1 - MBA v2.5.12 Slot 0500
Device 1:* virtualfloppy.slot.1 - VIRTUAL FLOPPY
Device 6:* usbfloppy.slot.1 - USB Floppy device
NOTE: The asterisk indicates that the device is enabled in the BIOS.
Device Name Examples:
Example of device names:
nic.slot.1 (network adapter 1 in PCI slot)
nic.emb.1 (network adapter 1 on system board)
hdd.emb.0 (hard drive C:)
cdrom.emb.0 (CD drive)
Device Name Lists Examples
SYSCFG
41