CLI Guide
Table Of Contents
- Dell EMC OpenManage Deployment Toolkit Version 6.0.1 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1/embnic1
- EmbNic1Nic2/embnic1nic2
- EmbNic2/embnic2
- EmbNic3/embnic3
- EmbNic3Nic4/embnic3nic4
- EmbNic4/embnic4
- EmbVideo/embvideoctrl
- IoatEngine/ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid/integratedraid
- IntegratedSas/integratedsas
- InternalSdCard/embsdcard
- InternalSdCardRedundancy/embsdcardredundancy
- InternalUsb/internalusb
- InternalUsb1/internalusbport1
- InternalUsb2/internalusbport2
- OsWatchdogTimer/oswatchdogtimer
- SriovGlobalEnable/sriov
- UsbPorts/usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- IscsiDev1Con
ChapType - IscsiDev1Con
DhcpEnDis - IscsiDev1ConnEnDis
- IscsiDev1ConnInterface
- IscsiDev1ConnProtocol
- IscsiDev1ConnTimeout
- IscsiDev1ConnVlanEnDis
- IscsiDev1ConnVlanId
- IscsiDev1ConnAuth
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse/datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher/dcustreamerprefetcher
- LogicalProc/logicproc
- Proc1Brand*
- Proc1Id*
- Proc1L2Cache*
- Proc1L3Cache*
- Proc1NumCores*
- Proc2Brand*
- Proc2Id*
- Proc2L2Cache*
- Proc2L3Cache*
- Proc2NumCores*
- Proc3Brand*
- Proc3Id*
- Proc3L2Cache*
- Proc3L3Cache*
- Proc3NumCores*
- Proc4Brand*
- Proc4Id*
- Proc4L2Cache*
- Proc4L3Cache
- Proc4NumCores*
- Proc64bit*
- ProcAdjCacheLine/adjcacheprefetch
- ProcBusSpeed*
- ProcCores/cpucore
- ProcCoreSpeed*
- ProcExecuteDisable/cpuxdsupport
- ProcHwPrefetcher/hwprefetcher
- ProcVirtualization / virtualization
- QpiBandwidthPriority / qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata / embsataraid
- eSataPort1
- eSataPort1Capacity*
- eSataPort1DriveType*
- eSataPort1Model*
- SataPortA / sata0
- SataPortACapacity*
- SataPortADriveType*
- SataPortAModel*
- SataPortB / sata1
- SataPortBCapacity*
- SataPortBDriveType*
- SataPortBModel*
- SataPortC / Sata2
- SataPortCCapacity*
- SataPortCDriveType*
- SataPortCModel*
- SataPortD / sata3
- SataPortDCapacity*
- SataPortDDriveType*
- SataPortDModel*
- SataPortE / sata4
- SataPortECapacity*
- SataPortEDriveType*
- SataPortEModel*
- SataPortF / sata5
- SataPortFCapacity*
- SataPortFDriveType*
- SataPortFModel*
- SataPortG / sata6
- SataPortGCapacity*
- SataPortGDriveType*
- SataPortGModel*
- SataPortH / sata7
- SataPortHCapacity*
- SataPortHDriveType*
- SataPortHModel*
- SataPortI / sata7
- SataPortICapacity*
- SataPortIDriveType*
- SataPortIModel*
- SataPortJ / sata7
- SataPortJCapacity*
- SataPortJDriveType*
- SataPortJModel*
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- System Security
- AcPwrRcvry / acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt/inteltxt
- NmiButton/nmibutton
- PasswordStatus/pwdlock
- PwrButton/powerbutton
- SetupPassword/setuppwd*
- SysPassword/syspwd*
- SystemCpldVersion*
- TcmActivation/tcmactivation
- TcmClear/tcmclear
- TcmSecurity/tcmsecurity
- TpmActivation/tpmactivation
- TpmClear/tpmclear
- TpmSecurity/tpmsecurity
- TpmStatus
- TpmInfo*
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- SecureBootMode
- TpmPpiBypassClear
- TpmPpiBypassProvision
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype*
- clearsel*
- controlpanelaccess
- deviceguid*
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt*
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev*
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults*
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset*
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version*
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
RAIDCFG Options And Arguments
Table below lists all of the valid options, parameters, and arguments for the RAIDCFG utility. For more information on valid
RAIDCFG options and their specific uses, see RAID Configuration Utility Options and Arguments.
Mandatory command line options must be present in the command. Optional command line options can be typed in any order
after the mandatory options have been typed. Many options have both a short and long format. Short and long format options
cannot be used in the same command line instance.
Table below shows some examples of valid and invalid short and long format command line instances. For an explanation of
the specific order for each option, see RAID Configuration Utility Options And Arguments. For a list of frequently used RAID
commands, see Quick Reference To RAIDCFG Commands.
NOTE: Some of the following options or arguments might not be available on all systems.
Table 332. RAIDCFG Short and Long Format Options
Option Valid Arguments Short Description Mandatory or Optional
No option
-h
-?
or
/?
NA Displays general usage information
for the utility. The usage information
consists of a comprehensive list of valid
options, parameters, and arguments.
Optional.
See General Help for
specific usage information.
-ac or
action
blink
Blinks the specified physical disks on
the specified controller.
See Blinking And Unblinking
Array Disks for specific
usage information.
ci
or
cancelinit
Cancels the slow or full initialization on
the selected virtual disk.
See Initializing Virtual
Disks for specific usage
information.
cc or consistencycheck Checks the consistency for a specified
virtual disk.
See Consistency Check For
Virtual Disk for specific
information.
ccc or
cancelconsistencycheck
Cancels the consistency check for a
specified virtual disk.
See Consistency Check For
Virtual Disk for specific
information.
chsk
or
changesecuritykey
Changes the encryption key of the
encryption-capable controller.
See Changing Encryption
Key for specific information.
crbd
or
cancelrebuild
Cancels the rebuild of the physical disk
associated with a specified virtual disk.
See Configuring Physical
Disk Rebuild for specific
information.
172 RAIDCFG