CLI Guide

Table Of Contents
Table 273. encryptkey
Option Sub-option Valid Arguments Description
Example:
A:>syscfg -- encryptkey=abcd
encryptkey= ABCD00000000000
000000000000000 0000000000
fiberchannel
Table 274. fiberchannel
Valid Arguments enable, disable
Description
Enables or disables embedded fiber channel. This option can be replicated.
Example:
A:>syscfg --fiberchannel=enable
fiberchannel=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
floppy
Table 275. floppy
Option
--floppy
Valid Arguments auto, off, readonly
Description
Sets the diskette drive controller to auto, off, or readonly. This option is available
on all supported systems that have a supported diskette drive. This option can be
replicated
Example:
A:>syscfg --floppy=auto
floppy=auto
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
formfactor
Table 276. formfactor
Valid Arguments read-only
Description
Displays the geometry of PowerEdge Blade systems. The option can have the
following values: halfheight (the Blade systems occupies 1 slot of the chassis),
halfheight, dualwide (the Blade system occupies 2 horizontal slots of the chassis),
fullheight (the Blade system occupies 2 vertical slots of the chassis), fullheight,
dualwide (the Blade system occupies 4 slots of the chassis) and quarterheight
(the Blade systems occupies half slot of the chassis).
SYSCFG 135