CLI Guide

Table Of Contents
MonitorMwait
Table 203. MonitorMwait
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: Enabled, Disabled
Description
Enables or disables Monitor/Mwait instructions. You can disable Monitor/Mwait only
when C state is disabled in Custom mode.
Example:
A:>syscfg --MonitorMwait=Enabled
MonitorMwait=Enabled
Applicable Systems Dells 12th generation PowerEdge and later systems
PowerSaver
Table 204. PowerSaver
Valid Arguments
On systems prior to Dells 13th generation PowerEdge systems: NA
On Dells 13th generation PowerEdge and later systems: Enabled, Disabled
Description
Enables or disables the power-saving Dell Active Power Controller (DAPC) algorithm.
Example:
A:>syscfg --PowerSaver=Enabled
PowerSaver=Enabled
Applicable Systems Dells 13th generation PowerEdge and later systems
ProcC1E/cpucle
Table 205. ProcC1E/cpucle
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: enable, disable
On Dells 12th generation PowerEdge systems and later systems: Enabled,
Disabled
Description
Enables or disables C1-E. By default, it is enabled. This option can be replicated.
Example:
A:>syscfg --cpucle=enable
cpucle=enable
Applicable Systems On Dells 11th generation PowerEdge systems and later systems
104 SYSCFG