Deployment Guide

Table Of Contents
Example1:
A:>syscfg --syspwd=<anotherpassword> --oldsyspwd=<password>
The password has been set.Please use a warm reboot to apply
the password to the system.
Example 2:
A:>syscfg --syspwd=<asyspassword> --
oldsyspwd=<
currentpassword>
The old password entered is incorrect. The new password
will not be set. Please try again.
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
opticaldrivectrl
Table 270. opticaldrivectrl
Valid Arguments enable, disable
Description
Enables or disables the optical CD-ROM controller.
Example:
A:>syscfg --opticaldrivectrl=enable
opticaldrivectrl=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
remashmedia
Table 271.
remashmedia
Valid Arguments read-only
Description
Displays the redundancy status of internal dual SD module. The status can be:
Full — Secure digital card (SD) 1 and 2 are functioning properly.
Lost — Either any of the secure digital cards or both are not functioning properly.
The option also displays the status of the individual SD cards as follows:
Active — The card is used for secure digital reads.
Standby — The card is receiving a copy of all secure digital reads.
Failed — An error is reported during a secure digital read or write.
Absent — No secure digital media is detected.
Oine — At boot, card identication signature is dierent from the non-volatile
storage value or card is the destination of a copying operation that is in progress.
Write Protected — The card is write-protected.
Example:
A:>syscfg --remflashmedia
Internal Dual SD ModuleRedundancy=Lost
SD1 status=Absent
SD1 status=Active
Applicable Systems All systems prior to PowerEdge 12G systems
119