Deployment Guide

Table Of Contents
Applicable Systems PowerEdge systems with Intel Xeon 7500 series
memintleave
Table 264. memintleave
Valid Arguments enable, disable
Description
Enables or disables the memory interleave mode. This option can be replicated.
Example:
A:>syscfg --memintleave=enable
memintleave=enable
NOTE: The memintleave option is same as Nodeinterleave option. For more
information, see Memory Settings group.
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
memremap
Table 265. memremap
Valid Arguments o, auto
Description
Sets the memory remapping to o or auto.
Example:
A:>syscfg --memremap=off
memremap=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
mouse
Table 266. mouse
Valid Arguments on, o
Description
Turns the mouse controller on or o.
This option can be replicated.
Example:
A:>syscfg --mouse=off
mouse=off
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
117