Deployment Guide

Table Of Contents
Table 200. IntelTxt/inteltxt (continued)
User password is not set.
Applicable Systems All PowerEdge 11G and later systems with Intel processors.
NmiButton/nmibutton
Table 201. NmiButton/nmibutton
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables or disables the Non-Maskable Interrupt (NMI) button on the front panel. The
NMI button can be used to alert the operating system in certain cases.
NOTE: This option configures Baseboard Management Controller (BMC) and
Remote Access Controller (RAC) settings.
Example:
A:>syscfg --nmibutton=enable
nmibutton=enable
Applicable Systems PowerEdge 11G and later systems
PasswordStatus/pwdlock
Table 202. PasswordStatus/pwdlock
Valid Arguments
On systems prior to 12G: lock, unlock
On 12G and later systems: Locked, Unlocked
Description
Locks the system password. To prevent the system password from being modified,
set this option to lockedand enable setup password. This field also prevents the
system password from being disabled by the user while the system boots.
Example:
A:>syscfg --pwdlock=lock
pwdlock=lock
Applicable Systems All PowerEdge systems.
PwrButton/powerbutton
Table 203. PwrButton/powerbutton
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables or disables the power button on the front panel.
98 SYSCFG