Deployment Guide

Table Of Contents
Table 58. MemOpMode/memoperatingmode (continued)
Applicable Systems PowerEdge 11G and later systems
MemOpVoltage/-dimmvoltage
Table 59. MemOpVoltage/-dimmvoltage
Valid Arguments
On systems prior to 12G: auto, 1.5
On 12G and later systems: AutoVolt, Volt15V
Description
Sets the DIMM voltage selection. When set to AutoVolt(default value), the system
automatically sets the voltage to the optimal setting based upon the DIMM capability
and the installed DIMM population. This option also enables setting the system DIMM
voltage to a higher (1.5V) setting if the DIMMs support multiple voltages and have
been set to a lower voltage.
NOTE: Volt15V represents 1.5 Volt.
Example:
A:>syscfg --dimmvoltage=auto
dimmvoltage=auto
Applicable Systems PowerEdge 12G and later systems.
MemTest/memtest
Table 60. MemTest/memtest
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables or disables the POST extended memory test.
Example:
A:>syscfg --MemTest=Enabled
MemTest=Enabled
Applicable Systems All PowerEdge systems
NodeInterleave/nodeinterleave
Table 61. NodeInterleave/nodeinterleave
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables node interleaving, if the system is configured with matching memory. If
set to disable (default), the system supports Non-Uniform Memory (NUMA)
architecture memory configurations. This field is active only if the memory
configuration can support node interleaving.
NOTE: The nodeinterleave option is same as memintleave option. For
more information, see memintleave.
SYSCFG 51