Deployment Guide

Table Of Contents
Table 355. RAIDCFG Error Codes and Messages (continued)
Error Code Message
230 Invalid VirtualDisk(VD) name specified. VD name can have alphanumeric
characters [A-Z,a-z,0-9,_,-] only. Also, VD name size must be less than
or equal to 15 characters
231 Error occurred while setting virtual disk as boot disk.
232 Error occurred while setting name for virtual disk.
233 Couldn't get boot virtual disk.
234 PCIe Link Speed could not be set for the RAID controller. Please check
if the controller has the capability to set/change its PCIe link speed.
235 PCIe Link Speed can be set to either 2 or 3 i.e. PCIe Generation 2.0 or
3.0.
236 PCIe Link Speed could not be retrieved for this RAID controller.Please
check if the controller has the PCIe link speed capability.
237 Please reset the controller before doing any further operation.
238 Boot Mode can be set to 0 (BIOS stop on error), 1 (BIOS continue on
error), 2 (Headless continue on error)
239 Boot Mode could not be set for the RAID controller.
240 Enable Auto Import can be set to 0 (No) or 1 (Yes).
241 Cannot discard the preserved cache because a foreign configuration is
present on the controller. Use '-ignoreconfig' or '-igncfg' to discard
the cache.
1000 Enable Auto Import property could not be set for the RAID controller.
1001 Invalid array disk list.
1002 Source or destination disk is in invalid state. Make sure that the
source disk is in online state, destination disk is in ready state, and
the size of the destination disk is greater than or equal to the size of
the source disk.
1003
Operation not allowed. Cannot set the array disk state to online.
1004 Operation not allowed. Cannot set the array disk state to offline.
1005 Invalid encrypted array disk list for the instant secure erase
operation.
1006 Sector drives 512B and 4KB must not be combined while creating a virtual
disk.
1007 Hot spare sector size for the virtual disk is not matching.
1008 sectorsize parameter is not found.
1009 Warning! Cannot assign global hotspare. Input array disk can act as a
hotspare only for virtual disks with matching sector size (4KB or 512B)
and supported T10 PI capability. Use "-force" option to discard the
warning.
1010
Force option is invalid for this operation on the specified controller.
1011 Input values for vdiskprotectioninfo and vdpi are 1 and 0.
1012 vdiskprotectioninfo or vdpi option is not available on the controller.
1013 Input array disks or hotspares are not PI-capable.
1014 Creation of RAID 10 virtual disk with Uneven Span failed.
218 Messages And Codes