Deployment Guide
system was off when AC power was lost, the system remains off when power is
restored. This option can be replicated.
Example:
A:>syscfg --acpower=on
acpower=on
Applicable Systems All PowerEdge systems.
AcPwrRcvryDelay
Table 198. AcPwrRcvryDelay
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Immediate, User, Random
Description
Specifies how the system supports the staggering of power-up after AC power has
been restored to the system.
Example:
A:>syscfg --AcPwrRcvryDelay=Immediate
AcPwrRcvryDelay=Immediate
Applicable Systems PowerEdge 12G and later systems
AcPwrRcvryUserDelay
Table 199. AcPwrRcvryUserDelay
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: <integer>
Description
Controls the user defined AC Recovery Delay. The delay must be in the range of 60
seconds to 240 seconds.
Example:
A:>syscfg --AcPwrRcvryUserDelay=60
AcPwrRcvryUserDelay=60
Applicable Systems PowerEdge 12G and later systems
AesNi
Table 200. AesNi
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Enabled, Disabled
Description
Displays the current status of Intel Processor AES-NI feature.
Example:
A:>syscfg --AesNi=Enabled
AesNi=Enabled
Applicable Systems PowerEdge 12G and later systems
92