Deployment Guide
NOTE: If set to DisabledOs, the Integrated NICs may still be available for
shared network access by the embedded management controller. This
function must be configured through the NIC management utilities provided
with your system.
Example:
A:>syscfg --IntegratedNetwork1=Enabled
IntegratedNetwork1=Enabled
Applicable Systems PowerEdge 12G and later systems
IntegratedNetwork2
Table 36. IntegratedNetwork2
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Enabled, DisabledOs
Description Enables or disables Integrated Network 2.
NOTE: If set to DisabledOs, the Integrated NICs may still be available for
shared network access by the embedded management controller. This
function must be configured through the NIC management utilities provided
with your system.
Example:
A:>syscfg --IntegratedNetwork2=Enabled
IntegratedNetwork2=Enabled
Applicable Systems PowerEdge 12G and later systems
IntegratedRaid/integratedraid
Table 37. IntegratedRaid/integratedraid
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the integrated RAID controller. This option can be replicated.
Example:
A:>syscfg --integratedraid=disable
integratedraid=disable
Applicable Systems All PowerEdge systems.
IntegratedSas/integratedsas
Table 38. IntegratedSas/integratedsas
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the integrated SAS controller. This option can be replicated.
44