Deployment Guide

On 12G and later systems: Enabled, Disabled
Description Enables or disables the boot sequence retry feature. When set to enable, the system
re-attempts to set the boot order after a 30-second time-out if the last boot attempt
has failed. This option can be replicated.
A:>syscfg --bootseqretry=enable
bootseqretry=enable
Applicable Systems All PowerEdge systems
HddFailover/hddfailover
Table 24. HddFailover/hddfailover
Valid Arguments
On systems prior to 12G: off, on
On 12G and later systems: Enabled, Disabled
Descriptionoff
Specifies the device in the Hard Disk Drive Sequence menu that has not been
attempted in the boot sequence. When set to on, all devices are attempted in an order
in which they are configured. When set to off, only the first device in the hard disk
sequence is attempted. This option can be replicated.
Example:
A:>syscfg --hddfailover=on
hddfailover=on
Applicable Systems All systems except PowerEdge 12G systems.
SetBootOrderFqdd
n
Table 25. SetBootOrderFqdd
n
Valid Arguments
On systems prior to 13G: NA
On 13G and later systems: <string>
Description
Displays the list of FQDDs representing the boot list to be applied on the next boot.
NOTE: The value of
n
in SetBootOrderFqdd
n
can be 1–16.
Example:
A:>syscfg --SetBootOrderFqdd1=xxxx,yyy,zzzz
SetBootOrderFqdd1=xxxx,yyy,zzzz
Applicable Systems PowerEdge 13G and later systems
SetLegacyHddOrderFqdd
n
Table 26. SetLegacyHddOrderFqdd
n
Valid Arguments
On systems prior to 13G: NA
On 13G and later systems: <string>
Description
Displays the list of FQDDs representing the legacy hard-disk drive list to be applied on
the next boot.
NOTE: The value of
n
in SetLegacyHddOrderFqdd
n
can be 1–16.
40