Deployment Guide
8
BMC Platform Events Filter Alert Messages
All possible Platform Event Filter (PEF) Alert Messages along with a description of each event are listed in the table below
Table 358. BMC PEF Alert Events
Event Description
Fan Probe Failure
The fan is running too slow or not at all.
Voltage Probe
Failure
The voltage is too low for proper operation.
Discrete Voltage
Probe Failure
The voltage is too low for proper operation.
Temperature Probe
Warning
The temperature is approaching excessively high or low limits.
Temperature Probe
Failure
The temperature is either too high or too low for proper operation.
Chassis Intrusion
Detected
The system chassis has been opened.
Redundancy (PS or
Fan) Degraded
Redundancy for the fans and/or power supplies has been reduced.
Redundancy (PS or
Fan) Lost
No redundancy remains for the system's fans and/or power supplies.
Processor Warning
A processor is running at less than peak performance or speed.
Processor Failure
A processor has failed.
PPS/VRM/DCtoDC
Warning
The power supply, voltage regulator module, or DC-to-DC converter is pending a failure condition.
Power
Supply/VRM/D2D
Failure
The power supply, voltage regulator module, or DC-to-DC converter has failed.
Hardware log is
full or emptied
Either an empty or a full hardware log requires administrator attention.
Automatic System
Recovery
The system is hung or is not responding and is taking an action configured by Automatic System
Recovery.
System Power
Probe Warning
The system is setting actions when a power consumption probe detects a warning value.
System Power
Probe Failure
The system is setting actions when a power consumption probe detects a failure value.
213