Deployment Guide

Mandatory Options
and Arguments
Optional Parameters Valid Parameters
Arguments
Description
NOTE: The wb and wt options are
supported on the following RAID controllers
only:
PERC 5/E Adapter, PERC 5/I Integrated,
PERC 5/i Adapter
PERC 6/i Integrated, PERC 6/i Adapter,
PERC 6/E Adapter
PERC 7, PERC 8, and PERC 9
wc — Write-Caching sets the controller to
send a write-request completion signal only
after the data is written to the disk.
nwc — No-Write-Caching specifies that the
controller does not send a write-request
completion signal after the data is written to
the disk.
fwb — Force write-back caching, enables the
write cache regardless of whether the
controller has a battery. If the controller does
not have a battery and force write-back
caching is used, data loss may occur in the
event of a power failure
NOTE: The -wpoption is optional and can
be added to the command line in any order
after the mandatory option combination.
For SCSI controllers, the value of LUN should
always be 0.
For SAS controllers, the value of enclosure can be
non-zero, in which case you must specify values
for channel, target, and enclosure.
-sf or secureflag
0, 1
Creates a secured virtual disk on controllers with
encryption capability and encryption key.
Example:
A:>raidcfg -ctrl -ac=cvd
-c=2
-ad=1:4,1:8 -sf=1
RAIDCFG Command successful!
Enumerating Array Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating array disks (hard-drives).
NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 315. Enumerating Array Disks (Hard Drives)
Mandatory Options
and Arguments
Optional Parameters Valid Parameters/
Arguments
Description
-ad -c=id or adisk
controllerid=id
NA NA
Lists all the array disks attached to the specified
RAID controller. This option combination is
mandatory.
162