Deployment Guide

Option Sub-option Valid Arguments Description
Example (to set and test the password for User ID
3):
A:>syscfg passwordaction --
userid=3 --action=setpassword --
password=bmcmaster passwordaction
userid=3 action=setpassword
password=*********
A:>syscfg passwordaction --
userid=3 --action=testpassword --
password=bmcmastor
Password test failed.
pefcfgparams
Table 293. pefcfgparams
Option Sub-option Valid Arguments Description
pefcfgparams or
pcp
Configures and displays PEF configuration
parameters. This option can be replicated.
--filter fanfail,
voltfail,
discretevoltfail
, tempwarn,
tempfail,
intrusion,
redundegraded,re
dunlost,
procwarn,
procfail,
powerwarn,
powerfail,
hardwarelogfail,
autorecovery,
batterywarn,
batteryfail,
powerabsent,
procabsent,
systempowerwarn,
systempowerfail
Specifies a PEF value. This sub-option can be
replicated.
For a complete list of all possible PEF messages
along a description of each event, see BMC
Platform Events Filter Alert Messages
--filteraction powercycle,
reset,
powerdown, power
reduction, none
Sets the event filter action for the filter
specified using the filter sub-option. This
sub-option depends on the filter sub-option.
This sub-option can be replicated.
--hostname <string>
Sets the host name (maximum of 62 printable
ASCII characters) for the BMC. This sub-option
can be replicated.
The hostname string must comprise only the
followig characters: hyphen (-) , underscore
(_) , and period (.) .
--filteralert
enable, disable
Enables or disables alerts for the filter specified
using the filter sub-option. This sub-option is
dependent on the filter sub-option. This sub-
option can be replicated.
129