Deployment Guide

Option Sub-option Valid Arguments Description
Example 1:
A:>syscfg --bootseq
Device 1: floppy.emb.0 -
Diskette Drive A:
Device 2: cdrom.emb.0 - CD-ROM
device
Device 3: hdd.emb.0 - Hard Drive
C:
Device 4: nic.emb.1 - Intel Boot
Agent Version 4.0.17
Device 5: nic.emb.2 - Intel Boot
Agent Version 4.0.17
Example 2:
A:>syscfg --nextboot=nic.emb.1
nextboot=nic.emb.1
nmibutton
Table 291. nmibutton
Option Sub-option Valid Arguments Description
--nmibutton
NA
enable, disable
Enables or disables the NMI button. This option
can be replicated.
Example:
A:>syscfg --nmibutton=enable
nmibutton=enable
passwordaction
Table 292. passwordaction
Option Sub-option Valid Arguments Description
passwordaction
Configures and tests the password for the
specified User ID. This option cannot be replicated.
All three sub-options, action, userid, and
password must be included in the command line.
NOTE: This option does not support 20
byte passwords.
--userid
2–16, if your system
has a DRAC 5 controller
Specifies the BMC User ID. This sub-option cannot
be replicated.
--action setpassword,
testpassword
Sets or tests the password for the specified User
ID. This sub-option cannot be replicated.
--password <string>
Sets the password (maximum of 16 printable ASCII
characters) for the specified BMC User ID. This
sub-option cannot be replicated.
128