Deployment Guide
Example:
A:>syscfg --sma=disable
sma=disable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
sysrev*
Table 276. sysrev*
Valid Arguments read-only
Description
Reports the system revision.
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
usb
Table 277. usb
Valid Arguments on, legacy, off
Description
Sets or reports the status of the USB port. When set to on, USB keyboards and mice
function only for systems with operating systems that have native USB support. When
set to legacy, USB keyboards and mice are supported through the BIOS to function in
operating systems that do not natively support USB. This option can be replicated.
Example:
A:>syscfg --usb=on
usb=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
usbflash
Table 278. usbflash
Valid Arguments auto, fdd, hdd
Description
Sets or reports the emulation for an USB flash device. The USB flash device can be
set to emulate a hard drive (HDD) or a diskette drive (FDD). This option can be
replicated.
Example:
A:>syscfg --usbflash=auto
usbflash=auto
Applicable Systems All systems prior to PowerEdge 12G systems.
vflash
Table 279. vflash
Valid Arguments enable, disable
Description
Enables or disables vflash on iDRAC.
121