Deployment Guide

serial1
Table 272. serial1
Valid Arguments disable, com1, com3, com1_bmc, bmcserial, bmclan, rac
Description
Configures or reports the first serial port communication port. This option can be
replicated.
bmcserial — maps serial port 1 to BMC Serial.
bmclan — routes the serial traffic destined for serial1 out to NIC1.
com1_bmc — maps serial port 1 to COM port 1 BMC.
rac — maps serial port 1 to the RAC device.
Example:
A:>syscfg --serial1=rac
serial1=rac
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
serial2
Table 273. serial2
Valid Arguments auto, disable, com2, com4
Description
Configures or reports the second serial port communication port. This option can be
replicated.
Example:
A:>syscfg --serial2=rac
serial2=rac
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
slotname
Table 274. slotname
Valid Arguments read-only
Description
Reports the slot name of the blade.
Example:
A:>syscfg --slotname
slotname=Slot5
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems.
sma
Table 275. sma
Valid Arguments enable, disable
Description
Enables or disables processor sequential memory access.
120