Deployment Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.4 User's Guide
- Introduction
- Pre-requisites and deployment
- Downloading DTK
- DTK Seamless package
- Setting up a directory structure for deployment
- Preparing the script files
- Using the sample DTK scripts to run a full deployment
- Editing the sample batch files to perform a complete system deployment
- Scripts for deployment on systems running windows
- Scripts for deployment on systems running Linux
- Replication scripts for deployment on systems running windows operating system
- Replication scripts for deployment on systems running Linux operating system
- Deployment scripts for systems running windows operating systems
- Deployment scripts for systems running Linux operating systems
- Other scripts for systems running Windows operating systems
- Other scripts for systems running Linux operating systems
- Editing example of TKENVSET and tkenvset
- Editing DTK task scripts
- Using DTK sample scripts to capture configuration information
- Preparing the operating system installation scripts
- Running the deployment scripts
- Deployment using removable boot media with a network connection media-based for systems running windows
- Media-based local deployment for systems running Microsoft Windows
- Media-Based local deployment with Networking enabled for systems running windows
- Deployment using removable boot media without a network media-based connection for systems running windows
- Network based deployment for systems running windows
- Using a third-party deployment solution framework for systems running windows
- Using Windows Pre-installation Environment driver CAB files for systems running Windows
- Deployment using Dell provided embedded Linux
- Deployment using customized embedded Linux
- Using a third-party deployment solution framework for systems running Linux
- Running Dell update packages on systems running embedded Linux
- Known issues and frequently asked questions
Table 4. Installation and configuration matrix (continued)
Compute sled to PowerEdge FD332
setup
Operating
system
installation
support
SYSCFG/RAIDCFG
configuration
support
Description
mapped to the two compute sleds (split
mode, one boot VD per compute sled)
Compute sled with PERC + 1 PowerEdge
FD332 with a dual PERC mapped to the
compute sled (joint mode) + single boot
VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled with PERC + 1 PowerEdge
FD332 with a dual PERC mapped to the
compute sled (split mode) + single boot
VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled without PERC + multiple
PowerEdge FD332 with a dual PERC
mapped to the compute sled (joint mode)
+ single boot VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS.
Compute sled without PERC + multiple
PowerEdge FD332 with a dual PERC
mapped to the compute sled (split mode)
+ single boot VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled without PERC + multiple
PowerEdge FD332 with a single PERC
mapped to the compute sled + single boot
VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled with PERC + multiple
PowerEdge FD332 with a dual PERC
mapped to the compute sled (joint mode)
+ single boot VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS.
Compute sled with PERC + multiple
PowerEdge FD332 with a dual PERC
mapped to the compute sled (split
mode) + single boot VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled with PERC + multiple
PowerEdge FD332 with a single PERC
mapped to compute sled + single boot VD
Yes Yes PERC controller with boot VD must be
the first in the boot order list of the
compute sled BIOS
Compute sled with PERC + PowerEdge
FD332 (single/multiple) with a dual PERC
mapped to the compute sled (joint mode)
+ multiple boot VD
No Yes No scenario to install operating system
with multiple boot VD
Compute sleds (with/without) PERC +
PowerEdge FD332 (single/multiple) with
a dual PERC mapped to the compute
sleds (split mode) + multiple boot VD
No Yes No scenario to install operating system
with multiple boot VD
Compute sled with PERC + PowerEdge
FD332 (single/multiple) with a single
PERC mapped to the compute sled +
multiple boot VD
No Yes No scenario to install operating system
with multiple boot VD
14 Pre-requisites and deployment