Deployment Guide

Table Of Contents
Table 182. MemPatrolScrub (continued)
On Dells 12th generation PowerEdge and later systems: Standard, Extended,
Disabled
Description
Sets the Memory Patrol Scrub frequency as Standard Mode, Extended Mode,
or Disabled.
Example:
A:>syscfg --MemPatrolScrub=Standard
MemPatrolScrub=Standard
Applicable Systems Dells 12th generation PowerEdge and later systems
MemRefreshRate
Table 183. MemRefreshRate
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: 1x, 2x
Description
Sets the Memory Refresh Rate as 1x or 2x
Example:
A:>syscfg --MemRefreshRate=1x
MemRefreshRate=1x
Applicable Systems Dells 12th generation PowerEdge and later systems
MemVolt
Table 184. MemVolt
Valid Arguments
On systems prior to Dells 12th generation PowerEdge systems: NA
On Dells 12th generation PowerEdge and later systems: AutoVolt, Volt15V,
Volt135V
NOTE: Volt15V represents 1.5 Volt and Volt135V represents 1.35 Volts.
Description
Sets the DIMM voltage selection.
Example:
A:>syscfg --MemVolt=AutoVolt
MemVolt=AutoVolt
Applicable Systems Dells 12th generation PowerEdge and later systems
MonitorMwait
Table 185. MonitorMwait
92 SYSCFG