Deployment Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.4 Command Line Interface Reference Guide
- Contents
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1/embnic1
- EmbNic1Nic2/embnic1nic2
- EmbNic2/embnic2
- EmbNic3/embnic3
- EmbNic3Nic4/embnic3nic4
- EmbNic4/embnic4
- EmbVideo/embvideoctrl
- IoatEngine/ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid/integratedraid
- IntegratedSas/integratedsas
- InternalSdCard/embsdcard
- InternalSdCardRedundancy/embsdcardredundancy
- InternalUsb/internalusb
- InternalUsb1/internalusbport1
- InternalUsb2/internalusbport2
- OsWatchdogTimer/oswatchdogtimer
- SriovGlobalEnable/sriov
- UsbPorts/usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse/datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher/dcustreamerprefetcher
- LogicalProc/logicproc
- Proc1Brand*
- Proc1Id*
- Proc1L2Cache*
- Proc1L3Cache*
- Proc1NumCores*
- Proc2Brand*
- Proc2Id*
- Proc2L2Cache*
- Proc2L3Cache*
- Proc2NumCores*
- Proc3Brand*
- Proc3Id*
- Proc3L2Cache*
- Proc3L3Cache*
- Proc3NumCores*
- Proc4Brand*
- Proc4Id*
- Proc4L2Cache*
- Proc4L3Cache
- Proc4NumCores*
- Proc64bit*
- ProcAdjCacheLine/adjcacheprefetch
- ProcBusSpeed*
- ProcCores/cpucore
- ProcCoreSpeed*
- ProcExecuteDisable/cpuxdsupport
- ProcHwPrefetcher/hwprefetcher
- ProcVirtualization / virtualization
- QpiBandwidthPriority / qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata / embsataraid
- eSataPort1
- eSataPort1Capacity*
- eSataPort1DriveType*
- eSataPort1Model*
- SataPortA / sata0
- SataPortACapacity*
- SataPortADriveType*
- SataPortAModel*
- SataPortB / sata1
- SataPortBCapacity*
- SataPortBDriveType*
- SataPortBModel*
- SataPortC / Sata2
- SataPortCCapacity*
- SataPortCDriveType*
- SataPortCModel*
- SataPortD / sata3
- SataPortDCapacity*
- SataPortDDriveType*
- SataPortDModel*
- SataPortE / sata4
- SataPortECapacity*
- SataPortEDriveType*
- SataPortEModel*
- SataPortF / sata5
- SataPortFCapacity*
- SataPortFDriveType*
- SataPortFModel*
- SataPortG / sata6
- SataPortGCapacity*
- SataPortGDriveType*
- SataPortGModel*
- SataPortH / sata7
- SataPortHCapacity*
- SataPortHDriveType*
- SataPortHModel*
- SataPortI / sata7
- SataPortICapacity*
- SataPortIDriveType*
- SataPortIModel*
- SataPortJ / sata7
- SataPortJCapacity*
- SataPortJDriveType*
- SataPortJModel*
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- System Security
- AcPwrRcvry / acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt/inteltxt
- NmiButton/nmibutton
- PasswordStatus/pwdlock
- PwrButton/powerbutton
- SetupPassword/setuppwd*
- SysPassword/syspwd*
- SystemCpldVersion*
- TcmActivation/tcmactivation
- TcmClear/tcmclear
- TcmSecurity/tcmsecurity
- TpmActivation/tpmactivation
- TpmClear/tpmclear
- TpmSecurity/tpmsecurity
- TpmStatus
- TpmInfo*
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype*
- clearsel*
- controlpanelaccess
- deviceguid*
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt*
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev*
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults*
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset*
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version*
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
Table 349. SYSCFG Error Codes and Messages
Error Code Message
178 Invalid configuration. Attempting to set cap when hardware does not
support setting.
179 Invalid Configuration Option.
180 Cannot execute command. Parameter is illegal because command sub-
function has been disabled or is unavailable.
181 Failed to report the removable flash media redundancy status.
182 Failed to report the Internal SD Module status.
183 Error locating the Virtual Media Key on the Modular system.
184 Error in setting the redundancy option for the Internal SD Modules.
185 Error in retrieving the redundancy option for the Internal SD Modules.
186 Error in setting the redundancy option on Modular systems for the
Internal SD Modules.
187 Error in retrieving the vFlash option.
188 Error in setting the vFlash option.
189 The set operation failed due to dependency.
190 The set operation failed because attribute is forced to a value.
191 Cannot disable this OrderedList’s entries.
192 The set operation failed because system is busy now . Try again later.
193 New value for the token not valid.
194 Token not found.
195 The set operation failed because System Services and/or CSIOR disabled.
196 The set operation failed due to pending System Password changes.
197 The set operation failed due to Password verification failure.
198 The set operation failed due to previously scheduled job.
199 The set operation failed because attribute is suppressed.
200 The set operation failed due to Generic failure.
201 XML path context creation failed.
202 Unable to parse XML.
203 Unable to connect data manager.
204 'root' privileges required to execute this application.
205 Invalid alert destination.
206 The set operation failed due to unspecified error.
207 Incorrect syntax for help. For more information about a particular
command, use the option '-h or --help' followed by the command name.
Example: %s -h --asset
208 System is busy now.Try again later.
209 The dependent option '%s' required for this subcommand should be
'enable'.
210 Some of the BIOS/IPMI tokens are ignored. See the log file (dtk.log) for
more information.
Messages And Codes 207