Deployment Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.4 Command Line Interface Reference Guide
- Contents
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1/embnic1
- EmbNic1Nic2/embnic1nic2
- EmbNic2/embnic2
- EmbNic3/embnic3
- EmbNic3Nic4/embnic3nic4
- EmbNic4/embnic4
- EmbVideo/embvideoctrl
- IoatEngine/ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid/integratedraid
- IntegratedSas/integratedsas
- InternalSdCard/embsdcard
- InternalSdCardRedundancy/embsdcardredundancy
- InternalUsb/internalusb
- InternalUsb1/internalusbport1
- InternalUsb2/internalusbport2
- OsWatchdogTimer/oswatchdogtimer
- SriovGlobalEnable/sriov
- UsbPorts/usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse/datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher/dcustreamerprefetcher
- LogicalProc/logicproc
- Proc1Brand*
- Proc1Id*
- Proc1L2Cache*
- Proc1L3Cache*
- Proc1NumCores*
- Proc2Brand*
- Proc2Id*
- Proc2L2Cache*
- Proc2L3Cache*
- Proc2NumCores*
- Proc3Brand*
- Proc3Id*
- Proc3L2Cache*
- Proc3L3Cache*
- Proc3NumCores*
- Proc4Brand*
- Proc4Id*
- Proc4L2Cache*
- Proc4L3Cache
- Proc4NumCores*
- Proc64bit*
- ProcAdjCacheLine/adjcacheprefetch
- ProcBusSpeed*
- ProcCores/cpucore
- ProcCoreSpeed*
- ProcExecuteDisable/cpuxdsupport
- ProcHwPrefetcher/hwprefetcher
- ProcVirtualization / virtualization
- QpiBandwidthPriority / qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata / embsataraid
- eSataPort1
- eSataPort1Capacity*
- eSataPort1DriveType*
- eSataPort1Model*
- SataPortA / sata0
- SataPortACapacity*
- SataPortADriveType*
- SataPortAModel*
- SataPortB / sata1
- SataPortBCapacity*
- SataPortBDriveType*
- SataPortBModel*
- SataPortC / Sata2
- SataPortCCapacity*
- SataPortCDriveType*
- SataPortCModel*
- SataPortD / sata3
- SataPortDCapacity*
- SataPortDDriveType*
- SataPortDModel*
- SataPortE / sata4
- SataPortECapacity*
- SataPortEDriveType*
- SataPortEModel*
- SataPortF / sata5
- SataPortFCapacity*
- SataPortFDriveType*
- SataPortFModel*
- SataPortG / sata6
- SataPortGCapacity*
- SataPortGDriveType*
- SataPortGModel*
- SataPortH / sata7
- SataPortHCapacity*
- SataPortHDriveType*
- SataPortHModel*
- SataPortI / sata7
- SataPortICapacity*
- SataPortIDriveType*
- SataPortIModel*
- SataPortJ / sata7
- SataPortJCapacity*
- SataPortJDriveType*
- SataPortJModel*
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- System Security
- AcPwrRcvry / acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt/inteltxt
- NmiButton/nmibutton
- PasswordStatus/pwdlock
- PwrButton/powerbutton
- SetupPassword/setuppwd*
- SysPassword/syspwd*
- SystemCpldVersion*
- TcmActivation/tcmactivation
- TcmClear/tcmclear
- TcmSecurity/tcmsecurity
- TpmActivation/tpmactivation
- TpmClear/tpmclear
- TpmSecurity/tpmsecurity
- TpmStatus
- TpmInfo*
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge 12G Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype*
- clearsel*
- controlpanelaccess
- deviceguid*
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt*
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev*
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults*
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset*
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version*
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
Table 4. Other delimiters
Delimiter Example Description
A string surrounded by double quotation
marks regardless of the white space
contained within, is interpreted as a
single SYSCFG argument.
syscfg --option="argument1
argument2"
considers
argument1
and
argument2
a single argument.
A double quotation mark preceded by a
backslash (\") is interpreted as a literal
double quotation mark (").
syscfg --
option="\"argument"
considers "argument as the argument.
Backslashes are interpreted literally,
unless they immediately precede a
double quotation mark. If an even
number of backslashes are followed
by a double quotation mark, then one
backslash (\) is taken for every pair
of backslashes (\\), and the double
quotation mark (") is interpreted as a
string delimiter.
syscfg --option="\
\"argument"
considers \ and argument as two
arguments.
If an odd number of backslashes are
followed by a double quotation mark,
then one backslash (\) is taken for
every pair of backslashes (\\) and the
double quotation mark is interpreted as
an escape sequence by the remaining
backslash, causing a literal double
quotation mark (") to be placed in the
SYSCFG argument.
syscfg --option="\\
\"argument"
considers \ "argument as the
argument.
Read And Write Commands
Options can report a certain value or set of values based on the presence of an argument. These read or write actions are
implied in the DTK command line arguments. The get, read, set, or write commands, for example, are not required.
NOTE: You cannot combine options that specify read or write actions in a command line instance.
Table 5. Read and Write Command Examples
Valid/Invalid DTK Command Line Example
valid
syscfg --option1 --option2
valid
syscfg --option1=arg --option2=arg
invalid
syscfg --option1=arg --option2
File Input And Output Commands
● Specify the file input using the -i <filename> command, where <filename> is the name of the input file.
● Specify the file output using the -o <filename> command, where <filename> is the name of the output file.
16
Command Syntax Overview