Deployment Guide

Table Of Contents
Table 234. embscsi1
Description
Turns the first embedded SCSI controller. This option is only valid for supported
systems that have an embedded SCSI controller. This option can be replicated.
Example:
A:>syscfg --embscsi1=on
embscsi1=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsi2
Table 235. embscsi2
Valid Arguments
on, off
Description
Turns the second embedded SCSI controller. This option is only valid for supported
systems that have an embedded SCSI controller. This option can be replicated.
Example:
A:>syscfg --embscsi2=on
embscsi2=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsiraid
Table 236. embscsiraid
Valid Arguments
raid, off, scsi
Description
Sets the specified value for the SCSI RAID controller. This option is only valid for
supported systems that have SCSI ROMB. Some systems do not support the scsi
argument. This option can be replicated.
CAUTION: If you change the controller from SCSI to RAID mode, data
loss may occur. Backup any data you must save before changing modes.
Example:
A:>syscfg --embscsiraid=raid
embscsiraid=raid
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
embscsiraidchb
Table 237. embscsiraidchb (continued)
Valid Arguments raid, scsi
Description
Sets the second channel on an embedded RAID controller to SCSI or RAID. This
option is only valid for systems that support RAID/RAID and RAID/SCSI settings for
channels A and B. This option can be replicated.
112 SYSCFG