CLI Guide
--redmem
Valid Arguments off, spare, mirror, DDDC
Description
Allows selection of the required redundant memory mode, or
disables redundant memory. This option can be replicated.
Example:
A:>syscfg --redmem=off
redmem=off
Applicable Systems PowerEdge systems with Intel Xeon 7500 series processor
--SerialDbgOut
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the RC/MRC Serial debug output.
Example:
A:>syscfg --SerialDbgOut=Enabled
SerialDbgOut=Enabled
Applicable Systems PowerEdge 12G and later systems.
--SysMemSize/--mem*
Valid Arguments
• On systems prior to 12G: read-only
• On 12G and later systems: read-only
Description
Displays the amount of main memory in the system.
Example:
A:>syscfg --mem
mem=500
Applicable Systems PowerEdge 11G and later systems.
--SnoopMode/--snoopfilter
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the snoop filter option from the system BIOS.
Example:
A:>syscfg --snoopfilter=enable
snoopfilter=enable
60