CLI Guide
--HddFailover/--hddfailover
Valid Arguments
• On systems prior to 12G: off, on
• On 12G and later systems: Enabled, Disabled
Descriptionoff
Specifies the device in the Hard Disk Drive Sequence menu that has
not been attempted in the boot sequence. When set to on, all
devices are attempted in an order in which they are configured.
When set to off, only the first device in the hard disk sequence is
attempted. This option can be replicated.
Example:
A:>syscfg --hddfailover=on
hddfailover=on
Applicable Systems All systems except PowerEdge 12G systems.
--SetBootOrderFqddn
Valid Arguments
• On systems prior to 13G: NA
• On 13G and later systems: <string>
Description
Displays the list of FQDDs representing the boot list to be applied on
the next boot.
NOTE: The value of n in SetBootOrderFqddn can be 1–16.
Example:
A:>syscfg --SetBootOrderFqdd1=xxxx,yyy,zzzz
SetBootOrderFqdd1=xxxx,yyy,zzzz
Applicable Systems PowerEdge 13G and later systems
--SetLegacyHddOrderFqddn
Valid Arguments
• On systems prior to 13G: NA
• On 13G and later systems: <string>
Description
Displays the list of FQDDs representing the legacy hard-disk drive list
to be applied on the next boot.
NOTE: The value of n in SetLegacyHddOrderFqddn can be 1–16.
Example:
A:>syscfg --SetLegacyHddOrderFqdd1=xxxx,yyy,zzzz
SetLegacyHddOrderFqdd1=xxxx,yyy,zzzz
Applicable Systems PowerEdge 13G and later systems