CLI Guide
Option Sub-option Valid Arguments Description
NOTE: This option applies only to
PowerEdge systems that are
configured with a BMC.
NOTE: This argument requires ACPI
support to function properly.
racreset*
Option Sub-option Valid Arguments Description
--racreset*
NA NA Resets the RAC. It cannot be
accompanied with any other option.
This option cannot be replicated.
serialcfgparams
Option Sub-option Valid Arguments Description
serialcfgparam
s or scp
Configures and displays serial
configuration parameters. This option
can be replicated.
--connectionmode basic,
terminal
Sets the connection mode used to
perform IPMI messaging to the BMC.
This sub-option can be replicated.
--msgcomm noflowctrl,
rtscts
Sets the IPMI message
communication flow control. This
suboption can be replicated.
--
msgcommdtrhangup
NA Reports the IPMI message
communication DTR hang-up. This
suboption cannot be replicated.
--msgcommbitrate 9600, 19200,
57600, 115200
Sets the IPMI message
communication baud rate in bits per
second (bps). This sub-option can be
replicated.
--
tmcfglineediting
enable,
disable
Sets the line editing value for terminal
mode configuration. This sub-option
can be replicated.
--tmcfgdelctrl del, bksp
Sets the delete control value for
terminal mode configuration. This
sub-option can be replicated.
--tmcfgechoctrl echo, noecho
Sets the echo control value for
terminal mode configuration. This
sub-option can be replicated.
--
tmcfghandshakectr
l
enable,
disable
Sets the handshake control value for
terminal mode configuration. This
sub-option can be replicated.
143