CLI Guide
Example:
A:>syscfg --embideraid=on
embideraid=on
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embnic1pxe
Valid Arguments enable, disable
Description
Enables or disables Preboot Execution Environment (PXE) on the first
embedded NIC. If PXE is disabled, the first NIC is not found in the
boot order. If PXE is enabled, the first NIC is placed at the end of the
boot order. This option is only present on systems that do not
support the embnic1 option. This option can be replicated.
Example:
A:>syscfg --embnic1pxe=enable
embnic1pxe=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embnic2pxe
Valid Arguments
enable, disable
Description
Enables or disables Preboot Execution Environment (PXE) on the
second embedded NIC. If PXE is disabled, the second NIC is not
found in the boot order. If PXE is enabled, the second NIC is placed
at the end of the boot order. This option is only present on systems
that do not support the embnic2 option. This option can be
replicated.
Example:
A:>syscfg --embnic2pxe=enable
embnic2pxe=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
--embnics
Valid Arguments
enable, disable
Description
Turns both the embedded NICs on or off. This option is only present
on systems that do not support the embnic1 and embnic2 options.
This option can be replicated.
Example:
A:>syscfg --embnics=enable
--embnics=enable
Applicable Systems All PowerEdge systems prior to PowerEdge 12G systems
113