CLI Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.3 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1 or embnic1
- EmbNic1Nic2 or embnic1nic2
- EmbNic2 or embnic2
- EmbNic3 or embnic3
- EmbNic3Nic4 or embnic3nic4
- EmbNic4 or embnic4
- EmbVideo or embvideoctrl
- IoatEngine or ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid or integratedraid
- IntegratedSas or integratedsas
- InternalSdCard or embsdcard
- InternalSdCardRedundancy or embsdcardredundancy
- InternalUsb or internalusb
- InternalUsb1 or internalusbport1
- InternalUsb2 or internalusbport2
- OsWatchdogTimer or oswatchdogtimer
- SriovGlobalEnable or sriov
- UsbPorts or usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse or datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher or dcustreamerprefetcher
- LogicalProc or logicproc
- Proc1Brand
- Proc1Id
- Proc1L2Cache
- Proc1L3Cache
- Proc1NumCores
- Proc2Brand
- Proc2Id
- Proc2L2Cache
- Proc2L3Cache
- Proc2NumCores
- Proc3Brand
- Proc3Id
- Proc3L2Cache
- Proc3L3Cache
- Proc3NumCores
- Proc4Brand
- Proc4Id
- Proc4L2Cache
- Proc4L3Cache
- Proc4NumCores
- Proc64bit
- ProcAdjCacheLine or adjcacheprefetch
- ProcBusSpeed
- ProcCores or cpucore
- ProcCoreSpeed
- ProcExecuteDisable or cpuxdsupport
- ProcHwPrefetcher or hwprefetcher
- ProcVirtualization or virtualization
- QpiBandwidthPriority or qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata or embsataraid
- eSataPort1
- eSataPort1Capacity
- eSataPort1DriveType
- eSataPort1Model
- SataPortA or sata0
- SataPortACapacity
- SataPortADriveType
- SataPortAModel
- SataPortB or sata1
- SataPortBCapacity
- SataPortBDriveType
- SataPortBModel
- SataPortC or Sata2
- SataPortCCapacity
- SataPortCDriveType
- SataPortCModel
- SataPortD or sata3
- SataPortDCapacity
- SataPortDDriveType
- SataPortDModel
- SataPortE or sata4
- SataPortECapacity
- SataPortEDriveType
- SataPortEModel
- SataPortF or sata5
- SataPortFCapacity
- SataPortFDriveType
- SataPortFModel
- SataPortG or sata6
- SataPortGCapacity
- SataPortGDriveType
- SataPortGModel
- SataPortH or sata7
- SataPortHCapacity
- SataPortHDriveType
- SataPortHModel
- SataPortI or sata7
- SataPortICapacity
- SataPortIDriveType
- SataPortIModel
- SataPortJ or sata7
- SataPortJCapacity
- SataPortJDriveType
- SataPortJModel
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- CollaborativeCpuPerfCtrl
- MemFrequency or memorypowermode
- MemPatrolScrub
- MemRefreshRate
- MemVolt
- MonitorMwait
- PowerSaver
- ProcC1E or cpucle
- ProcCStates or cstates
- ProcPwrPerf or cpupowermode
- ProcTurboMode or turbomode
- SysProfile or profile
- EnergyEfficientTurbo
- --ProcnTurboCoreNum
- EnergyPerformanceBias
- UncoreFrequency
- System Security
- --AcPwrRcvry/--acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt or inteltxt
- NmiButton or nmibutton
- PasswordStatus or pwdlock
- PwrButton or powerbutton
- SetupPassword or setuppwd
- SysPassword or syspwd
- SystemCpldVersion
- TcmActivation or tcmactivation
- TcmClear or tcmclear
- TcmSecurity or tcmsecurity
- TpmActivation or tpmactivation
- TpmClear/tpmclear
- TpmSecurity or tpmsecurity
- TpmStatus
- TpmInfo
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge YX2X Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype
- clearsel
- controlpanelaccess
- deviceguid
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
Table 8. SYSCFG General — h or help (continued)
Example:
A:>syscfg -h lanchannelaccess
lanchannelaccess: Reports LAN channel access information.
Sub-options:
pefalerting: Enable or disable PEF (Platform Event
Filter)alerting.
Arguments: enable | disable
ipmioverlan: Enable or disable
IPMI over LAN access.
Arguments: disable | alwaysavail
channelprivlmt: Sets the maximum privilege level that can
be accepted on the LAN channel.
Arguments: user | operator |administrator
i or infile
Table 9. SYSCFG General — i or infile
Valid Arguments <filename>
Description Directs the SYSCFG utility to take input from the .ini file. The utility searches the
file for a section heading identical to the utility name. An error is returned if the file
or section is not found. If the section is found, each name/value pair is applied to
the system. The names must match a valid option, and the arguments must be in
the proper format for the option. If an option is not available on a system and it is
specified in a file, the utility ignores the option. If any errors are found in the format
of the names or values, an error is returned and the options are not applied to the
system. If this option is used with other function command options, they are applied
in the order in which they appear on the command line, overriding any previous
commands.
Example:
A:>syscfg -i <filename>.ini
ix or inxmlfile
Table 10. SYSCFG General — ix or inxmlfile
Valid Arguments <filename>
Description
Directs the SYSCFG utility to receive input from the xml file. The utility searches
the BIOS option in the file. An error is returned if the file is not found. The provided
option must match a valid option, and the arguments must be in the proper format
for the option. If an option is not available on a system and it is specified in a file,
the utility ignores the option. If any errors are found in the format of the names or
values, an error is returned and the options are not applied to the system. If this
SYSCFG 21