CLI Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.3 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1 or embnic1
- EmbNic1Nic2 or embnic1nic2
- EmbNic2 or embnic2
- EmbNic3 or embnic3
- EmbNic3Nic4 or embnic3nic4
- EmbNic4 or embnic4
- EmbVideo or embvideoctrl
- IoatEngine or ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid or integratedraid
- IntegratedSas or integratedsas
- InternalSdCard or embsdcard
- InternalSdCardRedundancy or embsdcardredundancy
- InternalUsb or internalusb
- InternalUsb1 or internalusbport1
- InternalUsb2 or internalusbport2
- OsWatchdogTimer or oswatchdogtimer
- SriovGlobalEnable or sriov
- UsbPorts or usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse or datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher or dcustreamerprefetcher
- LogicalProc or logicproc
- Proc1Brand
- Proc1Id
- Proc1L2Cache
- Proc1L3Cache
- Proc1NumCores
- Proc2Brand
- Proc2Id
- Proc2L2Cache
- Proc2L3Cache
- Proc2NumCores
- Proc3Brand
- Proc3Id
- Proc3L2Cache
- Proc3L3Cache
- Proc3NumCores
- Proc4Brand
- Proc4Id
- Proc4L2Cache
- Proc4L3Cache
- Proc4NumCores
- Proc64bit
- ProcAdjCacheLine or adjcacheprefetch
- ProcBusSpeed
- ProcCores or cpucore
- ProcCoreSpeed
- ProcExecuteDisable or cpuxdsupport
- ProcHwPrefetcher or hwprefetcher
- ProcVirtualization or virtualization
- QpiBandwidthPriority or qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata or embsataraid
- eSataPort1
- eSataPort1Capacity
- eSataPort1DriveType
- eSataPort1Model
- SataPortA or sata0
- SataPortACapacity
- SataPortADriveType
- SataPortAModel
- SataPortB or sata1
- SataPortBCapacity
- SataPortBDriveType
- SataPortBModel
- SataPortC or Sata2
- SataPortCCapacity
- SataPortCDriveType
- SataPortCModel
- SataPortD or sata3
- SataPortDCapacity
- SataPortDDriveType
- SataPortDModel
- SataPortE or sata4
- SataPortECapacity
- SataPortEDriveType
- SataPortEModel
- SataPortF or sata5
- SataPortFCapacity
- SataPortFDriveType
- SataPortFModel
- SataPortG or sata6
- SataPortGCapacity
- SataPortGDriveType
- SataPortGModel
- SataPortH or sata7
- SataPortHCapacity
- SataPortHDriveType
- SataPortHModel
- SataPortI or sata7
- SataPortICapacity
- SataPortIDriveType
- SataPortIModel
- SataPortJ or sata7
- SataPortJCapacity
- SataPortJDriveType
- SataPortJModel
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- CollaborativeCpuPerfCtrl
- MemFrequency or memorypowermode
- MemPatrolScrub
- MemRefreshRate
- MemVolt
- MonitorMwait
- PowerSaver
- ProcC1E or cpucle
- ProcCStates or cstates
- ProcPwrPerf or cpupowermode
- ProcTurboMode or turbomode
- SysProfile or profile
- EnergyEfficientTurbo
- --ProcnTurboCoreNum
- EnergyPerformanceBias
- UncoreFrequency
- System Security
- --AcPwrRcvry/--acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt or inteltxt
- NmiButton or nmibutton
- PasswordStatus or pwdlock
- PwrButton or powerbutton
- SetupPassword or setuppwd
- SysPassword or syspwd
- SystemCpldVersion
- TcmActivation or tcmactivation
- TcmClear or tcmclear
- TcmSecurity or tcmsecurity
- TpmActivation or tpmactivation
- TpmClear/tpmclear
- TpmSecurity or tpmsecurity
- TpmStatus
- TpmInfo
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge YX2X Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype
- clearsel
- controlpanelaccess
- deviceguid
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
Table 352. RAIDCFG Error Codes and Messages (continued)
Error Code Message
176 Invalid array disks or failover drives selected for reconfigure/create
operation. Please make sure that all array disks and failover drives
associated with the virtual disk are selected.
177 The maximum number of partitions have already been created on one of the
selected array disk(s). Each array disk can hold portions (partitions)
of up to 10 virtual disks. This virtual disk cannot be created because
one or more array disk(s) have reached the partition limit.
178
The virtual disk is in use. Please close any applications that use the
virtual disk and unmount any file systems that reside on the virtual
disk.
179 The firmware version is not supported. Please update the firmware from
http://support.dell.com.
180 The specified device does not have enough free space to be used as
failover space for the specified virtual disk.
181 The operation failed. Please rescan the controller and retry the
operation.
182 The operation cannot be performed while a task is running on the
specified virtual disk.
183 The specified virtual disk has no dead disk segments.
184 The operation cannot be performed at this time. The firmware can
recondition a battery that has a Degraded or Power Low state. The
firmware will not recondition a battery that is functioning normally or
that has a Ready, Failed or Missing state.
185
The version of the controller firmware installed on your system does not
support this operation.
186 There are no disks of the correct type available to be assigned as a hot
spare.
187 There are no disks of sufficient size available to be assigned as a hot
spare.
188 There are no disks of the correct type and sufficient size available to
be assigned as a hot spare.
189 The Create Virtual Disk task was successful but the operating system may
not be aware of the new virtual disk.
191 The import of foreign configurations is complete. Some configurations
could not be imported.
192 Enable alarm command failed. The enclosure processor is busy or a
firmware download is in progress.
193 Disable alarm command failed. The enclosure processor is busy or a
firmware download is in progress.
194 Quiet alarm command failed. The enclosure processor is busy or a
firmware download is in progress.
195 An error occurred while resetting a temperature probe.
200 No array disks found!
201 Invalid Virtual Disk ID!
202 RAID Type & Size are required to create a virtual disk. Ensure that the
RAID type and the size are correct.
203 Invalid Environment command!
208 Messages And Codes