CLI Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.3 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1 or embnic1
- EmbNic1Nic2 or embnic1nic2
- EmbNic2 or embnic2
- EmbNic3 or embnic3
- EmbNic3Nic4 or embnic3nic4
- EmbNic4 or embnic4
- EmbVideo or embvideoctrl
- IoatEngine or ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid or integratedraid
- IntegratedSas or integratedsas
- InternalSdCard or embsdcard
- InternalSdCardRedundancy or embsdcardredundancy
- InternalUsb or internalusb
- InternalUsb1 or internalusbport1
- InternalUsb2 or internalusbport2
- OsWatchdogTimer or oswatchdogtimer
- SriovGlobalEnable or sriov
- UsbPorts or usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse or datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher or dcustreamerprefetcher
- LogicalProc or logicproc
- Proc1Brand
- Proc1Id
- Proc1L2Cache
- Proc1L3Cache
- Proc1NumCores
- Proc2Brand
- Proc2Id
- Proc2L2Cache
- Proc2L3Cache
- Proc2NumCores
- Proc3Brand
- Proc3Id
- Proc3L2Cache
- Proc3L3Cache
- Proc3NumCores
- Proc4Brand
- Proc4Id
- Proc4L2Cache
- Proc4L3Cache
- Proc4NumCores
- Proc64bit
- ProcAdjCacheLine or adjcacheprefetch
- ProcBusSpeed
- ProcCores or cpucore
- ProcCoreSpeed
- ProcExecuteDisable or cpuxdsupport
- ProcHwPrefetcher or hwprefetcher
- ProcVirtualization or virtualization
- QpiBandwidthPriority or qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata or embsataraid
- eSataPort1
- eSataPort1Capacity
- eSataPort1DriveType
- eSataPort1Model
- SataPortA or sata0
- SataPortACapacity
- SataPortADriveType
- SataPortAModel
- SataPortB or sata1
- SataPortBCapacity
- SataPortBDriveType
- SataPortBModel
- SataPortC or Sata2
- SataPortCCapacity
- SataPortCDriveType
- SataPortCModel
- SataPortD or sata3
- SataPortDCapacity
- SataPortDDriveType
- SataPortDModel
- SataPortE or sata4
- SataPortECapacity
- SataPortEDriveType
- SataPortEModel
- SataPortF or sata5
- SataPortFCapacity
- SataPortFDriveType
- SataPortFModel
- SataPortG or sata6
- SataPortGCapacity
- SataPortGDriveType
- SataPortGModel
- SataPortH or sata7
- SataPortHCapacity
- SataPortHDriveType
- SataPortHModel
- SataPortI or sata7
- SataPortICapacity
- SataPortIDriveType
- SataPortIModel
- SataPortJ or sata7
- SataPortJCapacity
- SataPortJDriveType
- SataPortJModel
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- CollaborativeCpuPerfCtrl
- MemFrequency or memorypowermode
- MemPatrolScrub
- MemRefreshRate
- MemVolt
- MonitorMwait
- PowerSaver
- ProcC1E or cpucle
- ProcCStates or cstates
- ProcPwrPerf or cpupowermode
- ProcTurboMode or turbomode
- SysProfile or profile
- EnergyEfficientTurbo
- --ProcnTurboCoreNum
- EnergyPerformanceBias
- UncoreFrequency
- System Security
- --AcPwrRcvry/--acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt or inteltxt
- NmiButton or nmibutton
- PasswordStatus or pwdlock
- PwrButton or powerbutton
- SetupPassword or setuppwd
- SysPassword or syspwd
- SystemCpldVersion
- TcmActivation or tcmactivation
- TcmClear or tcmclear
- TcmSecurity or tcmsecurity
- TpmActivation or tpmactivation
- TpmClear/tpmclear
- TpmSecurity or tpmsecurity
- TpmStatus
- TpmInfo
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge YX2X Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype
- clearsel
- controlpanelaccess
- deviceguid
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
UPINIT Options And Arguments
Table below lists the valid options and arguments for the UPINIT utility.
Table 346. UPINIT Options and Arguments
Option Valid Arguments Description
none
none
If no options are given, the tool outputs usage information. The usage
information is printed in the format shown below.
Example 1:
A:>upinit
upinit version 1.0
© 2012 Dell Inc. All rights reserved
upinit.sh --disk|-d=disk --size|-s=
size --file|-f=file
[--overwrite|-o] [--help|-h]
--help or -h prints help.
--disk or -d disk device on which to
create the Dell Utility Partition.
--size or -s Size in MB for the Dell
Utility Partition.
--file or -f filename of Dell Utility
Partition Image File.
--overwrite or -o Installs the Dell
Utility partition over an existing
one.
Example 2:
upinit --disk=/dev/sda --size=32 --
file=upimg.bin
In the example, upinit creates a Dell
Utility Partition of size 32 MB on
/dev/sda using upimg.bin file.
NOTE:
The --overwrite option should be used for upgrading/
downgrading purposes. The --size option is not required when using
the --overwrite option because the --overwrite option does not
resize an existing Dell Utility Partition. If any partitions exist, they are
deleted.
-h
none
This function command requires an argument that matches a valid option.
If the argument matches a valid option, that option’s usage information is
displayed. This option cannot be used with other options.
Windows PE Example:
upinit version 1.0
Copyright (c) 2002-2012 Dell Inc.
This utility creates a utility partition for your
system. This utility requires a Utility Partition
image file (upimg.bin) which can be found under /opt/
dell/toolkit/systems folder in the Deployment Toolkit
ISO. For more information, please consult the
Deployment Toolkit Documentation.
Usage:
upinit.bat [--overwrite] --disk=ID or
-d=ID --size=size or -s=size
UPINIT 191