Table 299. solcfgparams (continued)
Option Sub-option Valid Arguments Description
transmitting a partial SOL character data
packet. This option can be replicated.
--solcharsendthreshold 1255
Specifies that the BMC automatically sends
an SOL character data packet containing this
number of characters in increments of 5 (1
255) as soon as this number of characters
(or greater) has been accepted from the
baseboard serial controller into the BMC.
This option can be replicated.
--solbitrate
9600, 19200
Sets the serial channel communication bit
rate (in bps) with the BMC when SOL is
activated. This option can be replicated.
NOTE: The arguments for solbitrate
vary with various Dell systems. If an
argument valid for a particular Dell
system is entered for another system,
the Parameter out of range error
is displayed.
Example 1 (to display the current SOL
configuration):
A:>syscfg solcfgparams
solcfgparams solenable=enable
solprivlevel=administrator
solcharaccum interval=25
solcharsend threshold=25
solbitrate=9600
Example 2 (to set the SOL configuration
parameters):
A:>syscfg solcfgparams
--solenable=disable
--solprivlevel=administrator
--solcharaccum interval=25
--solcharsend threshold=100
--solbitrate=9600
solcfgparams solenable=disable
solprivlevel=administrator
solcharaccum interval=25
solcharsend threshold=100
solbitrate=9600
ssninfo
Table 300. ssninfo
Option Sub-option Valid Arguments Description
ssninfo
Displays information about the number of possible
active sessions and the number of currently active
sessions on all channels on the BMC. This option
cannot be replicated.
NOTE: All PowerEdge systems prior to
PowerEdge 12G systems.
138 SYSCFG