CLI Guide

Table Of Contents
Table 290. pefcfgparams (continued)
Option Sub-option Valid Arguments Description
--hostname <string>
Sets the host name (maximum of 62 printable
ASCII characters) for the BMC. This sub-
option can be replicated.
The hostname string must comprise only the
followig characters: hyphen (-) , underscore
(_) , and period (.) .
--filteralert
enable, disable
Enables or disables alerts for the filter
specified using the filter sub-option. This sub-
option is dependent on the filter sub-option.
This sub-option can be replicated.
--alertpolnum 1, 2, 3, 4
Specifies the alert policy entry number. This
sub-option can be replicated.
--alertpolstatus enable, disable
Enables or disables the alert policy specified
using the alertpolnum sub-option. This sub-
option can be replicated. This sub-option is
dependent on the alertpolnum sub-option.
Example: (to set the PEF configuration
parameters):
Example 1 (To configure the PEF so that the
system is powered down in response to a fan
failure event):
A:>syscfg pefcfgparams
--filter= fanfail--
filteraction=powerdown
pefcfgparams filter=fanfail
filteraction=powerdown
Example 2 (To configure the PEF so that
a PEF alert is not sent to the destination
IP address in response to a chassis intrusion
event):
A:>syscfg pefcfgparams
--filter= intrusion--
filteralert=disable
pefcfgparams filter= intrusion
filteralert=disable
powerbutton
Table 291. powerbutton
Option Sub-option Valid Arguments Description
--powerbutton
NA
enable, disable
Enables or disables the power button. This option
can be replicated.
132 SYSCFG