CLI Guide

Table Of Contents
Table 289. passwordaction (continued)
Option Sub-option Valid Arguments Description
--userid
216, if your system
has a DRAC 5 controller
Specifies the BMC User ID. This sub-option
cannot be replicated.
--action setpassword,
testpassword
Sets or tests the password for the specified User
ID. This sub-option cannot be replicated.
--password <string>
Sets the password (maximum of 16 printable
ASCII characters) for the specified BMC User ID.
This sub-option cannot be replicated.
Example (to set and test the password for User
ID 3):
A:>syscfg passwordaction --
userid=3 --action=setpassword
--password=bmcmaster
passwordaction userid=3
action=setpassword
password=*********
A:>syscfg passwordaction --
userid=3 --action=testpassword --
password=bmcmastor
Password test failed.
pefcfgparams
Table 290. pefcfgparams
Option Sub-option Valid Arguments Description
pefcfgparams or
pcp
Configures and displays PEF configuration
parameters. This option can be replicated.
--filter fanfail,
voltfail,
discretevoltfail
, tempwarn,
tempfail,
intrusion,
redundegraded,re
dunlost,
procwarn,
procfail,
powerwarn,
powerfail,
hardwarelogfail,
autorecovery,
batterywarn,
batteryfail,
powerabsent,
procabsent,
systempowerwarn,
systempowerfail
Specifies a PEF value. This sub-option can be
replicated.
For a complete list of all possible PEF
messages along a description of each
event, see BMC Platform Events Filter Alert
Messages
--filteraction
powercycle,
reset,
powerdown, power
reduction, none
Sets the event filter action for the filter
specified using the filter sub-option. This
sub-option depends on the filter sub-
option. This sub-option can be replicated.
SYSCFG 131