CLI Guide

Table Of Contents
Table 268. remflashmedia (continued)
Absent No secure digital media is detected.
Offline At boot, card identification signature is different from the non-volatile
storage value or card is the destination of a copying operation that is in progress.
Write Protected The card is write-protected.
Example:
A:>syscfg --remflashmedia
Internal Dual SD ModuleRedundancy=Lost
SD1 status=Absent
SD1 status=Active
serial1
Table 269. serial1
Valid Arguments disable, com1, com3, com1_bmc, bmcserial, bmclan, rac
Description
Configures or reports the first serial port communication port. This option can be
replicated.
bmcserial maps serial port 1 to BMC Serial.
bmclan routes the serial traffic destined for serial1 out to NIC1.
com1_bmc maps serial port 1 to COM port 1 BMC.
rac maps serial port 1 to the RAC device.
Example:
A:>syscfg --serial1=rac
serial1=rac
serial2
Table 270. serial2
Valid Arguments auto, disable, com2, com4
Description
Configures or reports the second serial port communication port. This option can be
replicated.
Example:
A:>syscfg --serial2=rac
serial2=rac
slotname
Table 271. slotname
Valid Arguments read-only
SYSCFG 121