CLI Guide
Table Of Contents
- Dell OpenManage Deployment Toolkit Version 5.3 Command Line Interface Reference Guide
- Introduction
- Command Syntax Overview
- DTK Seamless package
- SYSCFG
- Features
- SYSCFG General Options
- SYSCFG For BIOS Configuration
- SYSCFG BIOS commands
- BIOS Option Settings
- Boot Settings
- Integrated Devices
- EmbNic1 or embnic1
- EmbNic1Nic2 or embnic1nic2
- EmbNic2 or embnic2
- EmbNic3 or embnic3
- EmbNic3Nic4 or embnic3nic4
- EmbNic4 or embnic4
- EmbVideo or embvideoctrl
- IoatEngine or ioat
- IntegratedNetwork1
- IntegratedNetwork2
- IntegratedRaid or integratedraid
- IntegratedSas or integratedsas
- InternalSdCard or embsdcard
- InternalSdCardRedundancy or embsdcardredundancy
- InternalUsb or internalusb
- InternalUsb1 or internalusbport1
- InternalUsb2 or internalusbport2
- OsWatchdogTimer or oswatchdogtimer
- SriovGlobalEnable or sriov
- UsbPorts or usbports
- MmioAbove4Gb
- Usb3Setting
- CurrentEmbVideoState
- InternalSdCardPrimaryCard
- Network Settings
- Memory Settings
- Miscellaneous Settings
- One-Time Boot
- Processor Settings
- DataReuse or datareuse
- DcuIpPrefetcher
- DcuStreamerPrefetcher or dcustreamerprefetcher
- LogicalProc or logicproc
- Proc1Brand
- Proc1Id
- Proc1L2Cache
- Proc1L3Cache
- Proc1NumCores
- Proc2Brand
- Proc2Id
- Proc2L2Cache
- Proc2L3Cache
- Proc2NumCores
- Proc3Brand
- Proc3Id
- Proc3L2Cache
- Proc3L3Cache
- Proc3NumCores
- Proc4Brand
- Proc4Id
- Proc4L2Cache
- Proc4L3Cache
- Proc4NumCores
- Proc64bit
- ProcAdjCacheLine or adjcacheprefetch
- ProcBusSpeed
- ProcCores or cpucore
- ProcCoreSpeed
- ProcExecuteDisable or cpuxdsupport
- ProcHwPrefetcher or hwprefetcher
- ProcVirtualization or virtualization
- QpiBandwidthPriority or qpibandwidthpriority
- QpiSpeed
- RtidSetting
- ProcnControlledTurbo
- ProcConfigTdp
- ProcX2Apic
- SATA Settings
- EmbSata or embsataraid
- eSataPort1
- eSataPort1Capacity
- eSataPort1DriveType
- eSataPort1Model
- SataPortA or sata0
- SataPortACapacity
- SataPortADriveType
- SataPortAModel
- SataPortB or sata1
- SataPortBCapacity
- SataPortBDriveType
- SataPortBModel
- SataPortC or Sata2
- SataPortCCapacity
- SataPortCDriveType
- SataPortCModel
- SataPortD or sata3
- SataPortDCapacity
- SataPortDDriveType
- SataPortDModel
- SataPortE or sata4
- SataPortECapacity
- SataPortEDriveType
- SataPortEModel
- SataPortF or sata5
- SataPortFCapacity
- SataPortFDriveType
- SataPortFModel
- SataPortG or sata6
- SataPortGCapacity
- SataPortGDriveType
- SataPortGModel
- SataPortH or sata7
- SataPortHCapacity
- SataPortHDriveType
- SataPortHModel
- SataPortI or sata7
- SataPortICapacity
- SataPortIDriveType
- SataPortIModel
- SataPortJ or sata7
- SataPortJCapacity
- SataPortJDriveType
- SataPortJModel
- SecurityFreezeLock
- Serial Communication
- Slot Disablement
- System Information
- System Profile Settings
- CollaborativeCpuPerfCtrl
- MemFrequency or memorypowermode
- MemPatrolScrub
- MemRefreshRate
- MemVolt
- MonitorMwait
- PowerSaver
- ProcC1E or cpucle
- ProcCStates or cstates
- ProcPwrPerf or cpupowermode
- ProcTurboMode or turbomode
- SysProfile or profile
- EnergyEfficientTurbo
- --ProcnTurboCoreNum
- EnergyPerformanceBias
- UncoreFrequency
- System Security
- --AcPwrRcvry/--acpower
- AcPwrRcvryDelay
- AcPwrRcvryUserDelay
- AesNi
- IntelTxt or inteltxt
- NmiButton or nmibutton
- PasswordStatus or pwdlock
- PwrButton or powerbutton
- SetupPassword or setuppwd
- SysPassword or syspwd
- SystemCpldVersion
- TcmActivation or tcmactivation
- TcmClear or tcmclear
- TcmSecurity or tcmsecurity
- TpmActivation or tpmactivation
- TpmClear/tpmclear
- TpmSecurity or tpmsecurity
- TpmStatus
- TpmInfo
- TpmCommand
- SecureBoot
- SecureBootPolicy
- UefiVariableAccess
- UEFI Boot Settings
- DTKTORACADM
- SYSCFG Options On PowerEdge Systems Prior To PowerEdge YX2X Systems
- Sub Options And Arguments For power Option
- Sub Options And Arguments For tcm Option
- Sub Options And Arguments For tpm Option
- SYSCFG For BMC And Remote Access Controller Configuration
- bmcversion
- chassistype
- clearsel
- controlpanelaccess
- deviceguid
- encryptkey
- fiberchannel
- floppy
- formfactor
- hddfailover
- hpcmode
- htassist
- idecdrom
- idracgui
- lpt
- memdynamicpower
- memintleave
- memremap
- mouse
- noraidprompt
- oldsetuppwd
- oldsyspwd
- opticaldrivectrl
- remflashmedia
- serial1
- serial2
- slotname
- sma
- sysrev
- usb
- usbflash
- vflash
- identify
- idracversion
- kvmstatusonlcd
- lancfgparams
- lanchannelaccess
- lanchannelinfo
- lanuseraccess
- lcd1
- lcd2
- loaddefaults
- nextboot
- nmibutton
- passwordaction
- pefcfgparams
- powerbutton
- powerctl
- racreset
- serialcfgparams
- serialchannelaccess
- serialchannelinfo
- serialuseraccess
- solaction
- solcfgparams
- ssninfo
- useraction
- username
- version
- virutualmedia
- SYSCFG For State Configuration
- SYSCFG for System Configuration
- SYSCFG For IPv6 Configuration
- PCI Reporting
- RAIDCFG
- Features
- Supported RAID Controllers
- RAIDCFG Options And Arguments
- RAID Configuration Utility Options And Arguments
- General Help
- Enumerating RAID Controllers
- Creating Virtual Disks
- Enumerating Array Disks
- Blinking And Unblinking Array Disks
- Enumerating Virtual Disks
- Deleting Virtual Disks
- Increasing Virtual Disk Size
- Setting A Virtual Disk As Bootable Virtual Disk
- Blinking And Unblinking Virtual Disks
- Setting Virtual Disk Name
- Setting Environment Variables
- RAID Replication Options
- Assigning, Unassigning, And Listing Global Hot Spares
- Importing And Clearing Foreign Configurations
- Importing Secured Foreign Configuration
- Displaying Foreign Key Ids
- Creating Encryption Key
- Changing Encryption Key
- Deleting Encryption Key
- Configuring Physical Disk Rebuild
- Configuring Array Disk As RAID
- Configuring Physical Disk State
- Replacing Physical Disk Of A Virtual Disk
- Consistency check for virtual disk
- Erasing Encrypted Physical Disk
- Discarding Preserved Cache
- Initializing Virtual Disks
- Resetting The Controller
- Enabling And Disabling Persistent Dedicated Hot Spares
- Setting And Displaying The PCIe Link Speed
- Setting Boot Mode
- Configuring Auto Import
- Miscellaneous Options
- Quick Reference To RAIDCFG Commands
- UPINIT
- Messages And Codes
- BMC Platform Events Filter Alert Messages
- Sample File Formats
NOTE: Some of the following options or arguments might not be available on all systems.
NOTE: For options that use text strings such as username, password, hostname, and community string, using some
characters such as <space>, <, >, | , or = on the command line can be misinterpreted by the command line parser and cause
errors.
NOTE: The following options or arguments are also applicable to DRAC 5.
The following tables document valid options, sub-options, and arguments along with a description of the expected behavior of
each option and suboption. Options, sub-options, and arguments are case-sensitive. All options, sub-options, and pre-defined
arguments are lowercase unless explicitly stated otherwise. Some features that must be noted while reading this section are:
● Unless otherwise specified, all sub-options to options are optional.
● If a sub-option is not specified for an option, all valid sub-option values are displayed for the option. If sub-options are
specified, then only those suboptions are reported.
● Wherever options or sub-options take empty strings as input, the string NULL should be input. For example, options such as
username and suboptions such as commstring and hostname can take an empty string as input.
bmcversion
Table 245. bmcversion options
Option Sub-option Valid Arguments Description
bmcversion
Displays the version information for the BMC
and the BMC firmware. This option cannot be
replicated.
--devid
NA Reports the BMC device ID.
--devrevision
NA Reports the BMC device revision.
--majorfwversion
NA Reports the BMC device major firmware revision.
--minorfwversion
NA
Reports the BMC device minor firmware revision.
Example:
A:>syscfg bmcversion devid=32
devrevision=0
majorfwversion=0
minorfwversion=40
chassistype
Table 246. chassistype
Option Sub-option Valid Arguments Description
--chassistype*
NA NA
Identifies the Chassis Management Controller
(CMC). The possible values are 9 (M1000e),
10 (VRTX), and 0 (others).
Example:
A:>syscfg -- chassistype
chassistype=10 (VRTX)
SYSCFG 113