Reference Guide

--SecurityFreezeLock
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: Enabled, Disabled
Description
Sends the Security Freeze Lock command to the embedded SATA
drives during power-on self-test (POST). The option is applicable
only to ATA and AHCI, and not to RAID.
Example:
A:>syscfg --SecurityFreezeLock=Enabled
SecurityFreezeLock=Enabled
Applicable Systems PowerEdge 12G and later systems
Serial Communication
You can manage the serial port settings using the options in this group.
--ConTermType/--conterm
Valid Arguments
On systems prior to 12G: vt100, ansi
On 12G and later systems: Vt100, Vt220, Ansi
Description
Sets the console terminal type. On some systems, vt100 may also set
the terminal type to vt220. This option is available on all supported
systems that support console redirection. This option can be
replicated.
Example:
A:>syscfg --conterm=vt100
conterm=vt100
Applicable Systems All PowerEdge systems
--ExtSerialConnector/--extserial
Valid Arguments
On systems prior to 12G: com1, com2, rad
On 12G and later systems: Serial1, Serial2,
RemoteAccDeviceDescription
Description
Sets the behavior of the external serial connector. When set to
com1 , the BIOS maps the external serial connector to COM port 1.
The com1 setting is the default.
When set to com2 , the external serial connector is routed to the
COM2 interface. Terminal escape sequences can toggle the external
connector between the system (COM2) and the remote access
device.
87