Reference Guide

Example:
A:>syscfg --oswatchdogtimer=enable
oswatchdogtimer=enable
Applicable Systems All PowerEdge systems.
--SriovGlobalEnable/--sriov
Valid Arguments
On systems prior to 12G: enable, disable
On 12G and later systems: Enabled, Disabled
Description
Enables or disables support for Single Root I/O Virtualization (SR-IOV)
devices.
Example:
A:>syscfg --sriov=disable
sriov=disable
Applicable Systems All PowerEdge systems.
--UsbPorts/--usbports
Valid Arguments
On systems prior to 12G: enable, enablebackonly, disable
On 12G and later systems: AllOn, OnlyBackPortsOn, AllOff
Description
Enables or disables USB ports. When set to enable, it enables all user
accessible USB ports. When set to enablebackonlyor
OnlyBackPortsOn, the front user-accessible ports are disabled.
When set to disable or AllOff, both front and back user accessible
ports are disabled. This option can be replicated.
Example:
A:>syscfg --usbports=enable
usbports=enable
Applicable Systems All PowerEdge systems.
--MmioAbove4Gb
Valid Arguments
On systems prior to 12G: NA
On 12G and later systems: Enabled, Disabled
Description
This field helps in enabling support for PCIe devices that require large
amount of memory. Enable this option only for 64-bit operating
systems.
Example:
A:>syscfg --MmioAbove4Gb=Enabled
MmioAbove4Gb=Enabled
52