Reference Guide
• On 12G and later systems: Enabled, DisabledOs
Description Enables or disables Integrated Network 1.
NOTE: If set to DisabledOs, the Integrated NICs may still be
available for shared network access by the embedded
management controller. This function must be configured
through the NIC management utilities provided with your
system.
Example:
A:>syscfg --IntegratedNetwork1=Enabled
IntegratedNetwork1=Enabled
Applicable Systems PowerEdge 12G and later systems
--IntegratedNetwork2
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Enabled, DisabledOs
Description Enables or disables Integrated Network 2.
NOTE: If set to DisabledOs, the Integrated NICs may still be
available for shared network access by the embedded
management controller. This function must be configured
through the NIC management utilities provided with your
system.
Example:
A:>syscfg --IntegratedNetwork2=Enabled
IntegratedNetwork2=Enabled
Applicable Systems PowerEdge 12G and later systems
--IntegratedRaid/--integratedraid
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the integrated RAID controller. This option can be
replicated.
Example:
A:>syscfg --integratedraid=disable
integratedraid=disable
Applicable Systems All PowerEdge systems.
49