Reference Guide
Blinking And Unblinking Array Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for blinking and
unblinking array disks (hard drives).
NOTE: You can also use pdisk or -pd instead of adisk or -ad to specify an array disk.
Table 17. Blinking And Unblinking Array Disks
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
-ad -ad=
ch:targ,ch:tar
g ,... -
ac=blink -
c=id or adisk
adisk=
channel:target
,
channel:target
,... -ac=blink
controllerid=
id vdisk=id
NA NA
Blinks the specified physical disks on the
specified controller.
Example:
A:>raidcfg -ad -ad=0:0:1 -
ac=blink -c=4
RAIDCFG Command successful!
-ad -ad=
ch:targ,ch:tar
g ,... -ac=
unblink -c=id
or adisk adisk=
channel:target
,
channel:target
,... -ac=
unblink
controllerid=
id vdisk=id
NA NA
Unblinks the specified physical disks on
the specified controller.
Example:
A:>raidcfg –ad –ad=0:0:1 –
ac=unblink –c=4
RAIDCFG Command successful!
Enumerating Virtual Disks
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for enumerating
virtual disks.
Table 18. Enumerating Virtual Disks
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
—vd or vdisk
NA NA
Lists all the virtual disks for each
controller along with the array disks that
make up each virtual disk. This option is
mandatory.
179