Reference Guide
--ClusterOnDie
Valid Arguments
• On systems prior to 12G: NA
• On 12G and later systems: Enabled, Disabled
Description Enables or disables the Cluster On Die option. When enabled, the
feature enhances the performance of the system with two caching
agents.
A:>syscfg --ClusterOnDie=Enabled
ClusterOnDie=Enabled
Applicable Systems PowerEdge 12G and later systems
Miscellaneous Settings
You can manage the miscellaneous settings using the options in this group.
--AssetTag/--asset*
Valid Arguments
• On systems prior to 12G: read-only
• On 12G and later systems: read-only
Description Reports or sets the customer-programmable asset tag number for a
system. This value can be replicated.
NOTE: The Asset Tag is a string assigned to a system, usually by
an administrator, for security or tracking purposes. The Asset Tag
can be up to 10 characters long and can contain only printable
US-ASCII characters. For more information on delimiters, see
Command Line Option Delimiters.
Example:
A:>syscfg --asset=<ASSETTAG>
asset=ASSETTAG
Applicable Systems All PowerEdge systems except Blade systems
--ErrPrompt/--f1f2promptonerror
Valid Arguments
• On systems prior to 12G: enable, disable
• On 12G and later systems: Enabled, Disabled
Description
Enables or disables the BIOS to prompt F1 or F2 error codes.
Example:
A:>syscfg --f1f2promptonerror=enable
f1f2promptonerror=enable
Applicable Systems PowerEdge 10G and later systems
60