Reference Guide
Table 32. Deleting Encryption Key
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
-ctrl -c=id -
ac=dsk
or
controller
controllerid=i
d
action=deletes
ecuritykey
NA NA
Deletes the encryption key of the
encryption-capable controller.
Example:
A:>raidcfg -ctrl -c=2 -ac=dsk
Configuring Physical Disk Rebuild
The following table lists the RAIDCFG options, parameters, and pre-defined arguments for configuring
the rebuild of the physical disks associated with a virtual disk.
Table 33. Configuring the Disk Rebuild
Mandatory
Options and
Arguments
Optional
Parameters
Valid Parameters
Arguments
Description
-vd -ac=rbd -
ad|-pd=
ch:targ:encl -
c=id
or
vdisk
action=rebuild
adisk|
pdisk=channel:
target:enclosu
re
controllerid=i
d
NA NA
Rebuilds the physical disk associated
with a specified virtual disk.
Example:
A:>raidcfg -vd -ac=rbd -ad=0:1
-c=2
-vd -ac=crbd -
ad|-pd=
ch:targ:encl -
c=id
or
vdisk
action=cancelr
ebuild adisk|
pdisk=channel:
target:enclosu
re
controllerid=i
d
NA NA
Cancels the rebuild of the physical disk
associated with a specified virtual disk.
Example:
A:>raidcfg -vd -ac=crbd -
ad=0:1 -c=2
192